Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/97010
Title: | Carrier-based modulation strategy and its implementation for indirect matrix converter under unbalanced grid voltage conditions | Authors: | Liu, X. Wang, P. Blaabjerg, Frede Loh, Poh Chiang |
Keywords: | DRNTU::Engineering::Electrical and electronic engineering | Issue Date: | 2012 | Source: | Liu, X., Blaabjerg, F., Loh, P. C., & Wang, P. (2012). Carrier-based modulation strategy and its implementation for indirect matrix converter under unbalanced grid voltage conditions. 2012 15th International Power Electronics and Motion Control Conference (EPE/PEMC), LS6a.2-1 - LS6a.2-7. | Conference: | International Power Electronics and Motion Control Conference and Exposition Europe Congress (15th : 2012 : Novi Sad, Serbia) | Abstract: | Indirect Matrix Converter (IMC) using two stages configuration is topologically more flexible than 3×3 Direct Matrix Converter (DMC). Due to the absence of passive components, the input and output terminals of matrix converters are coupled physically with the same instantaneous power. The output voltages are decided by the input grid voltages whereas the input currents are drawn from the load currents. This paper presents a carrier-based modulation strategy for IMC under unbalanced grid voltage conditions to produce high quality balanced output voltages and sinusoidal input currents without low order harmonics. Step-by-step implementations for the modulation schemes are explained in detail, inclusive of sequence components detection of grid voltages, modulation for current source rectifier (CSR), variable slope triangle carrier generation, online fictitious dc-link voltage calculations and modulation strategy for voltage source inverter (VSI) with compensated dc-link voltage. Theoretical analysis and mathematical proof for balanced outputs and sinusoidal inputs are provided to show validities of the proposed method. The maximum input-to-output voltage transfer ratio is found to be less than 0.866 and is highly related to the unbalance ratio and phase angle difference between positive and negative sequence grid voltages. Simulation and experimental results are provided to validate the effectiveness of the modulation schemes for IMC. | URI: | https://hdl.handle.net/10356/97010 http://hdl.handle.net/10220/11729 |
DOI: | 10.1109/EPEPEMC.2012.6397486 | Schools: | School of Electrical and Electronic Engineering | Rights: | © 2012 IEEE. | Fulltext Permission: | none | Fulltext Availability: | No Fulltext |
Appears in Collections: | EEE Conference Papers |
SCOPUSTM
Citations
20
10
Updated on Mar 5, 2024
Page view(s) 20
624
Updated on Mar 18, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.