Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/103666
Title: Operating characteristics and performance improvements of a 500 W traveling-wave thermoacoustic electric generator
Authors: Wang, Kai
Sun, Daming
Zhang, Jie
Xu, Ya
Zou, Jiang
Wu, Ke
Qiu, Limin
Huang, Zhiyi
Keywords: DRNTU::Engineering::Materials::Energy materials
Issue Date: 2015
Source: Wang, K., Sun, D., Zhang, J., Xu, Y., Zou, J., Wu, K., et al. (2015). Operating characteristics and performance improvements of a 500 W traveling-wave thermoacoustic electric generator. Applied energy, in press.
Series/Report no.: Applied energy
Abstract: Traveling-wave thermoacoustic electric generator has drawn increasing attention due to its great prospect in energy conversion. In this work, a traveling-wave thermoacoustic electric generator capable of generating about 500 W electric power is studied numerically and experimentally. The performances and the operating characteristics of the system under different working conditions are tested and analyzed. The maximum electric powers can be obtained with electric load resistance around 100–120 Ω, and the highest thermal-to-electric efficiencies can be achieved at much larger load resistances. The efficiency at low load resistance is relatively small due to the large pressure amplitudes inside the thermoacoustic system, which increases the dissipations. The variation trends of the electric power and the thermal-to-electric efficiency with the load resistance intrinsically result from the changes of the corresponding acoustic impedance of the linear alternators, which determines the output performance of the thermoacoustic engine meanwhile. The distributions of the acoustic power losses are then calculated and firstly illustrated quantitatively. It is shown that the resonator causes most of the acoustic power losses, and the losses in hot heat exchanger, thermal buffer tube, and feedback tube are also significant. The output performance of the system can be improved by increasing the heating temperature and the mean pressure. A maximum electric power of 473.6 W and a highest thermal-to-electric efficiency of 14.5% are achieved experimentally when the mean pressure is 2.48 MPa and the heating temperature is 650 °C. A pair of linear alternators with a larger swept volume and appropriate acoustic impedances is finally designed to couple with the thermoacoustic torus directly. Numerical results show that the maximum electric power can be increased to 718 W and 1005 W when the mean pressures are kept at 2.48 MPa and 3.20 MPa, corresponding to the improvements of 42.6% and 29.4% compared with those of the original system.
URI: https://hdl.handle.net/10356/103666
http://hdl.handle.net/10220/25826
DOI: 10.1016/j.apenergy.2015.03.085
Research Centres: Energy Research Institute @ NTU (ERI@N) 
Rights: © 2015 Elsevier Ltd. This is the author created version of a work that has been peer reviewed and accepted for publication by Applied energy, Elsevier Ltd. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.apenergy.2015.03.085].
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:ERI@N Journal Articles

Files in This Item:
File Description SizeFormat 
Operating characteristics of a 500 W traveling-wave thermoac_NotMarked.pdf2.27 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 10

51
Updated on Mar 22, 2024

Web of ScienceTM
Citations 10

34
Updated on Oct 29, 2023

Page view(s) 20

725
Updated on Mar 29, 2024

Download(s) 10

402
Updated on Mar 29, 2024

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.