mirage

A low-power bio-sensor interface with wide measurement range

DSpace/Manakin Repository

 

Search DR-NTU


Advanced Search Subject Search

Browse

My Account

A low-power bio-sensor interface with wide measurement range

Show simple item record

dc.contributor.author Chai, Y.
dc.contributor.author Chan, Pak Kwong
dc.date.accessioned 2010-08-31T05:56:37Z
dc.date.available 2010-08-31T05:56:37Z
dc.date.copyright 2008
dc.date.issued 2010-08-31T05:56:37Z
dc.identifier.citation Chai, Y., & Chan, P. K. (2008). A low-power bio-sensor interface with wide measurement range. In proceedings of the 9th IEEE Asia Pacific Conference on Circuits and Systems: Macau, China, (pp.117-120).
dc.identifier.uri http://hdl.handle.net/10220/6380
dc.description.abstract A new low-power high dynamic range conductanceto- frequency converter, using relaxation oscillator approach, is proposed for bio-sensor interfacing applications. Enhanced by a leakage current compensation technique, the interface has immunity against input pad ESD leakage current as well as hum noise. The output frequency is linear with respect to sensor conductance, with the maximum systematic error of 0.58% and average error of 0.46% for nanowire sensor resistance from 100 MΩ ~ 1 GΩ. For 2% systematic error, the resistance range of the interfacing system can attain from 5 MΩ to 5 GΩ. The biosensor interface is designed using CSM 0.18 μm CMOS technology, which dissipates 37.2 μW at a single supply of 1.8V and the maximum sensor current.
dc.format.extent 4 p.
dc.language.iso en
dc.rights © 2008 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder. http://www.ieee.org/portal/site This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.
dc.subject DRNTU::Engineering::Electrical and electronic engineering::Electronic apparatus and materials
dc.title A low-power bio-sensor interface with wide measurement range
dc.type Conference Paper
dc.contributor.conference IEEE Asia Pacific Conference on Circuits and Systems (2008 : Macau)
dc.contributor.school School of Electrical and Electronic Engineering
dc.identifier.doi http://dx.doi.org/10.1109/APCCAS.2008.4745974
dc.description.version Published version

Files in this item

Files Size Format View
A Low-Power Bio ... Wide Measurement Range.pdf 613.3Kb PDF View/Open

This item appears in the following Collection(s)

Show simple item record