mirage

A tuneable micro-optofluidic biconvex lens with mathematically predictable focal length

DSpace/Manakin Repository

 

Search DR-NTU


Advanced Search Subject Search

Browse

My Account

A tuneable micro-optofluidic biconvex lens with mathematically predictable focal length

Show simple item record

dc.contributor.author Song, Chaolong
dc.contributor.author Nguyen, Nam-Trung
dc.contributor.author Tan, Say-Hwa
dc.contributor.author Asundi, Anand Krishna
dc.date.accessioned 2012-04-12T00:48:54Z
dc.date.available 2012-04-12T00:48:54Z
dc.date.copyright 2010
dc.date.issued 2012-04-12
dc.identifier.citation Song, C., Nguyen, N. T., Tan, S. H. & Asundi, A. K. (2010). A tuneable micro-optofluidic biconvex lens with mathematically predictable focal length. Microfluidics and Nanofluidics, 9(4-5), 889-896.
dc.identifier.uri http://hdl.handle.net/10220/7733
dc.description.abstract Recent research efforts have been increasingly focused on the development of microlenses. Of great interest are in-plane optofluidic lenses due to the possibility of integrating them directly into a microfluidic network. Furthermore, the tunability of optofluidic lenses makes them more adaptive to lab-on-a-chip (LOC) system for biological and chemical analysis. However, the predictability of the performance of the current optofluidic lenses is limited by the lack of a simple explicit mathematical model. Previously, we proposed a model based on dipole flow theory to calculate the flow field in a circular chamber where the optofluidic lens is formed. However, this method assumes that both the core and cladding liquids have the same viscosity. In this article, hydrodynamic spreading theory is used to model the opening angles of the core stream and the cladding stream at the entrance of the circular chamber. Subsequently, the curvature of the lens interface for each corresponding opening angle of the core stream can be determined. The focal length of the optofluidic lens formed in the circular chamber can be analytically formulated, which can help to determine the position of focal point for a given flow condition. Experiments were carried out to verify this new model. Ray-tracing method was used experimentally and numerically to measure the focal length. The theoretical results agree well with both experimental and numeric results.
dc.language.iso en
dc.relation.ispartofseries Microfluidics and nanofluidics
dc.rights © 2010 Springer-Verlag. This is the author created version of a work that has been peer reviewed and accepted for publication by Microfluidics and Nanofluidics, Springer-Verlag. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [DOI: http://dx.doi.org/10.1007/s10404-010-0608-1].
dc.subject DRNTU::Engineering::Mechanical engineering
dc.title A tuneable micro-optofluidic biconvex lens with mathematically predictable focal length
dc.type Journal Article
dc.contributor.school School of Mechanical and Aerospace Engineering
dc.identifier.doi http://dx.doi.org/10.1007/s10404-010-0608-1
dc.description.version Accepted version
dc.identifier.rims 152456

Files in this item

Files Size Format View
195. A tuneable ... edictable focal length.pdf 678.7Kb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Statistics

Total views

All Items Views
A tuneable micro-optofluidic biconvex lens with mathematically predictable focal length 271

Total downloads

All Bitstreams Views
195. A tuneable micro-optofluidic biconvex lens with mathemarically predictable focal length.pdf 125
Optofluidic biconvex lens Manuscript.pdf 7

Top country downloads

Country Code Views
United States of America 58
China 35
Singapore 6
France 4
India 4

Top city downloads

city Views
Mountain View 40
Beijing 15
Singapore 6
Hefei 4
Gainesville 3