Tests on seismically damaged reinforced concrete structural walls repaired using fiber reinforced polymers.

Show simple item record

dc.contributor.author Li, Bing.
dc.contributor.author Lim, Chee Leong.
dc.date.accessioned 2012-08-10T03:40:23Z
dc.date.available 2012-08-10T03:40:23Z
dc.date.copyright 2010
dc.date.issued 2012-08-10
dc.identifier.citation Li, B., & Lim, C. L. (2010). Tests on Seismically Damaged Reinforced Concrete Structural Walls Repaired Using Fiber-Reinforced Polymers. Journal of Composites for Construction, 14(5), 597–608.
dc.identifier.uri http://hdl.handle.net/10220/8363
dc.description.abstract This paper presents the results of an experimental study on the seismic performance of axially loaded reinforced concrete RC walls with boundary elements confined by limited transverse reinforcement. These specimens were initially subjected to axial compression loading and cyclic lateral loading to failure, and subsequently repaired and subjected to loading again. The test specimens include two low-rise walls of aspect ratio 1.125 and two medium-rise walls of aspect ratio 1.625. Results show that significant drift capacities were achieved from the strengthened walls. The performance of the repaired walls was similar to the original walls before repair in terms of the flexural behavior, shear strength, and ductility capacities. While the fiber-reinforced polymer FRP anchorage may undergo premature failure, it however failed only after the peak lateral strength of the repaired wall was attained. This paper demonstrates that repair of damaged RC walls using FRP is able to restore the performance of damaged RC walls while also serving as repair method of relative ease.
dc.language.iso en
dc.relation.ispartofseries Journal of Composites for Construction
dc.rights © 2010 ASCE. This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of Composites for Construction, ASCE. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: http://dx.doi.org/10.1061/(ASCE)CC.1943-5614.0000110.
dc.subject DRNTU::Engineering.
dc.title Tests on seismically damaged reinforced concrete structural walls repaired using fiber reinforced polymers.
dc.type Journal Article
dc.contributor.school School of Civil and Environmental Engineering
dc.identifier.doi http://dx.doi.org/10.1061/(ASCE)CC.1943-5614.0000110
dc.description.version Accepted version

Files in this item

Files Size Format View
186. Tests on S ... er-Reinforced Polymers.pdf 1.524Mb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Statistics

Total views

All Items Views
Tests on seismically damaged reinforced concrete structural walls repaired using fiber reinforced polymers. 224

Total downloads

All Bitstreams Views
186. Tests on Seismically Damaged Reinforced Concrete Structural Walls Repaired Using Fiber-Reinforced Polymers.pdf 200
ASCE CC LiB -1 Tests on Seismically Damaged Reinforced Concrete Structural Walls Repaired Using Fiber-Reinforced Polymers.pdf 17

Top country downloads

Country Code Views
United States of America 62
Iran 29
India 14
China 11
Singapore 7

Top city downloads

city Views
Mountain View 29
Singapore 7
Simi Valley 6
Tirana 6
Beijing 5