Show simple item record

dc.contributor.author Li, Bing.
dc.contributor.author Pan, Tso-Chien.
dc.contributor.author Tran, Cao Thanh Ngoc.
dc.date.accessioned 2012-08-13T02:54:12Z
dc.date.available 2012-08-13T02:54:12Z
dc.date.copyright 2009
dc.date.issued 2012-08-13
dc.identifier.citation Li, B., Pan, T. C., & Tran, C. T. N. (2009). Seismic behavior of nonseismically detailed interior beam-wide column and beam-wall connections. ACI Structural Journal, 106(5), 591-599.
dc.identifier.uri http://hdl.handle.net/10220/8368
dc.description.abstract Six full-scale nonseismically detailed reinforced concrete (RC) interior beam-wide column and beam-wall joints with zero to high axial compression loads were tested to investigate the seismic behavior of the joints. Quasi-static cyclic loading, simulating earthquake actions, was applied. The overall performance of each test assembly was examined in terms of lateral load capacity, drift, stiffness, energy dissipation capacity, and nominal joint shear stress. Three levels of axial compressive column loads were investigated to determine how this variable would influence the performance of the joints. All the specimens failed adjacent to the joint panel with gradual strength deterioration and low attainment of structural stiffness. The low attainment of stiffness and strength was attributed to the slip of the longitudinal bars through the joint core. The test results showed that RC interior beam-wide column joints and beam-wall joints with nonseismic design and detailing attained a drift ratio of 2.0% without significant strength degradation. It was thus concluded that such joints could also possess inherent ductility for adequate response to unexpected moderate earthquakes.
dc.language.iso en
dc.relation.ispartofseries ACI structural journal
dc.rights © 2009 American Concrete Institute. This paper was published in ACI structural journal and is made available as an electronic reprint (preprint) with permission of American Concrete Institute. The paper can be found at the following official URL: [http://www.concrete.org/PUBS/JOURNALS/OLJDetails.asp?Home=SJ&ID=51663099]. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law.
dc.subject DRNTU::Engineering.
dc.title Seismic behavior of nonseismically detailed interior beam-wide column and beam-wall connections.
dc.type Journal Article
dc.contributor.school School of Civil and Environmental Engineering
dc.identifier.openurl http://www.concrete.org/PUBS/JOURNALS/OLJDetails.asp?Home=SJ&ID=51663099
dc.description.version Published version

Files in this item

Files Size Format View
Seismic Behavio ... Beam-Wall Connections.pdf 386.0Kb PDF View/Open

This item appears in the following Collection(s)

Show simple item record

Statistics

Total views

All Items Views
Seismic behavior of nonseismically detailed interior beam-wide column and beam-wall connections. 188

Total downloads

All Bitstreams Views
Seismic Behavior of Nonseismically Detailed Interior Beam-Wide Column and Beam-Wall Connections.pdf 46
ACI-Li Bing-7 Seismic Behavior of Nonseismically Detailed Interior Joints _Ngoc.pdf 9

Top country downloads

Country Code Views
United States of America 15
China 9
Singapore 9
Algeria 4
Pakistan 4

Top city downloads

city Views
Mountain View 12
Singapore 9
Beijing 4
Biskra 4
Santiago 2