Show simple item record

dc.contributor.author Li, Bing.
dc.contributor.author Pan, Tso-Chien.
dc.contributor.author Tran, Cao Thanh Ngoc.
dc.date.accessioned 2012-08-13T02:54:12Z
dc.date.available 2012-08-13T02:54:12Z
dc.date.copyright 2009
dc.date.issued 2012-08-13
dc.identifier.citation Li, B., Pan, T. C., & Tran, C. T. N. (2009). Seismic behavior of nonseismically detailed interior beam-wide column and beam-wall connections. ACI Structural Journal, 106(5), 591-599.
dc.identifier.uri http://hdl.handle.net/10220/8368
dc.description.abstract Six full-scale nonseismically detailed reinforced concrete (RC) interior beam-wide column and beam-wall joints with zero to high axial compression loads were tested to investigate the seismic behavior of the joints. Quasi-static cyclic loading, simulating earthquake actions, was applied. The overall performance of each test assembly was examined in terms of lateral load capacity, drift, stiffness, energy dissipation capacity, and nominal joint shear stress. Three levels of axial compressive column loads were investigated to determine how this variable would influence the performance of the joints. All the specimens failed adjacent to the joint panel with gradual strength deterioration and low attainment of structural stiffness. The low attainment of stiffness and strength was attributed to the slip of the longitudinal bars through the joint core. The test results showed that RC interior beam-wide column joints and beam-wall joints with nonseismic design and detailing attained a drift ratio of 2.0% without significant strength degradation. It was thus concluded that such joints could also possess inherent ductility for adequate response to unexpected moderate earthquakes.
dc.language.iso en
dc.relation.ispartofseries ACI structural journal
dc.rights © 2009 American Concrete Institute.
dc.subject DRNTU::Engineering.
dc.title Seismic behavior of nonseismically detailed interior beam-wide column and beam-wall connections.
dc.type Journal Article
dc.contributor.school School of Civil and Environmental Engineering
dc.identifier.openurl http://www.concrete.org/PUBS/JOURNALS/OLJDetails.asp?Home=SJ&ID=51663099

Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Statistics

Total views

All Items Views
Seismic behavior of nonseismically detailed interior beam-wide column and beam-wall connections. 92

Total downloads

All Bitstreams Views
ACI-Li Bing-7 Seismic Behavior of Nonseismically Detailed Interior Joints _Ngoc.pdf 9

Top country downloads

Country Code Views
Singapore 5
China 4

Top city downloads

city Views
Singapore 5
Beijing 4