Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/96504
Title: | Analysis of physiological responses from multiple subjects for emotion recognition | Authors: | Gu, Yuan Wong, Kai-Juan Tan, Su-Lim |
Keywords: | DRNTU::Engineering::Computer science and engineering | Issue Date: | 2012 | Source: | Gu, Y., Wong, K.-J., & Tan, S.-L. (2012). Analysis of physiological responses from multiple subjects for emotion recognition. 2012 IEEE 14th International Conference on e-Health Networking, Applications and Services (Healthcom). | Conference: | IEEE International Conference on e-Health Networking, Applications and Services (14th : 2012 : Beijing, China) | Abstract: | Psychological disorders, including emotion and behavioral disorders, are common in the modern society. For example, previous studies by the New Zealand Mental Health Survey and the US National Co-morbidity Surveys (NCS), have found that the incidence of depression from ages 18 to 32 to be around 18%. Thus, there is a need to effectively monitor the emotional or affective states of these patients with psychological illness. Whilst real-time and continuous psychological monitoring systems are still not prevalent, the monitoring of physiological signals are made easier with mobile sensors that can be attached to the human body. These physiological signals can then be processed using an embedded processor to provide an alternative means for automatic emotion recognition. However, for such a system to be developed, the relationship between physiological and psychological signals has to be understood. This paper aims to address this by investigating the relationship between the emotional experiences from multiple subjects and their physiological responses, including the skin conductance, heart rate, respiration and movements of the facial muscles. In summary, preliminary evaluations described in this paper demonstrated that the heart rate, respiration, blood volume pulse and electromyography signals have an impact on the recognition rate achievable by the proposed multi-user physiological response-based emotion detection system. | URI: | https://hdl.handle.net/10356/96504 http://hdl.handle.net/10220/11940 |
DOI: | 10.1109/HealthCom.2012.6379388 | Schools: | School of Computer Engineering | Rights: | © 2012 IEEE. | Fulltext Permission: | none | Fulltext Availability: | No Fulltext |
Appears in Collections: | SCSE Conference Papers |
SCOPUSTM
Citations
20
9
Updated on Mar 12, 2024
Page view(s) 50
546
Updated on Mar 26, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.