Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/103597
Title: Correction of errors in tandem mass spectrum extraction enhances phosphopeptide identification
Authors: Hao, Piliang
Ren, Yan
Sze, Siu Kwan
Tam, James P.
Keywords: DRNTU::Science::Biological sciences
Issue Date: 2013
Source: Hao, P., Ren, Y., Tam, J. P., & Sze, S. K. (2013). Correction of Errors in Tandem Mass Spectrum Extraction Enhances Phosphopeptide Identification. Journal of Proteome Research, 12(12), 5548-5557.
Series/Report no.: Journal of proteome research
Abstract: The tandem mass spectrum extraction of phosphopeptides is more difficult and error-prone than that of unmodified peptides due to their lower abundance, lower ionization efficiency, the cofragmentation with other high-abundance peptides, and the use of MS3 on MS2 fragments with neutral losses. However, there are still no established methods to evaluate its correctness. Here we propose to identify and correct these errors via the combinatorial use of multiple spectrum extraction tools. We evaluated five free and two commercial extraction tools using Mascot and phosphoproteomics raw data from LTQ FT Ultra, in which RawXtract 1.9.9.2 identified the highest number of unique phosphopeptides (peptide expectation value <0.05). Surprisingly, ProteoWizzard (v. 3.0.3476) extracted wrong precursor mass for most MS3 spectra. Comparison of the top three free extraction tools showed that only 54% of the identified spectra were identified consistently from all three tools, indicating that some errors might happen during spectrum extraction. Manual check of 258 spectra not identified from all three tools revealed 405 errors of spectrum extraction with 7.4% in selecting wrong precursor charge, 50.6% in selecting wrong precursor mass, and 42.1% in exporting MS/MS fragments. We then corrected the errors by selecting the best extracted MGF file for each spectrum among the three tools for another database search. With the errors corrected, it results in the 22.4 and 12.2% increase in spectrum matches and unique peptide identification, respectively, compared with the best single method. Correction of errors in spectrum extraction improves both the sensitivity and confidence of phosphopeptide identification. Data analysis on nonphosphopeptide spectra indicates that this strategy applies to unmodified peptides as well. The identification of errors in spectrum extraction will promote the improvement of spectrum extraction tools in future.
URI: https://hdl.handle.net/10356/103597
http://hdl.handle.net/10220/19341
ISSN: 1535-3893
DOI: http://dx.doi.org/10.1021/pr4004486
Rights: © 2013 American Chemical Society. This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of Proteome Research, American Chemical Society. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1021/pr4004486].
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:SBS Journal Articles

Files in This Item:
File Description SizeFormat 
MS3_Extraction.pdf918.05 kBAdobe PDFThumbnail
View/Open

Google ScholarTM

Check

Altmetric

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.