dc.contributor.authorTan, K.-H.
dc.contributor.authorNguyen, T.-T.
dc.date.accessioned2014-12-11T06:46:17Z
dc.date.available2014-12-11T06:46:17Z
dc.date.copyright2014en_US
dc.date.issued2014
dc.identifier.citationTan, K.-H., & Nguyen, T.-T. (2014). Experimental and numerical evaluation of composite floor systems under fire conditions. Journal of constructional steel research, 105, 86-96.en_US
dc.identifier.urihttp://hdl.handle.net/10220/24435
dc.description.abstractThis paper presents novel experimental results and observations from three one-quarter scale tests on two-way concrete slabs supported by protected steel edge beams under fire conditions. The sizes of the protected secondary edge beams were varied to study the effect of beam stiffness on the fire behaviour of the assemblies. Test results showed that as the stiffness of the protected secondary edge beams increased, the slab central deflection decreased and failure of the slab occurred later. However, composite action between the edge beams and the concrete slab plays a key role in mobilising this beneficial effect. Once the composite slab-beam action is weakened by cracks in the slab over the main or secondary edge beams, the benefit associated with a greater stiffness of the edge beams is lost. Tensile membrane action was mobilised at a deflection equal to 0.9 to 1.0 of the slab thickness irrespective of the bending stiffness of the edge beams. The commencement of tensile membrane stage was marked by one of three indicators: (a) concrete cracks which formed a peripheral compressive ring in the slab; (b) horizontal in-plane displacements along the slab edges; and (c) horizontal and vertical displacements of four corner protected steel columns. The test results were used to validate a finite element model developed using Abaqus/Explicit. Good correlation between the predicted and experimental results was obtained.en_US
dc.description.sponsorshipASTAR (Agency for Sci., Tech. and Research, S’pore)
dc.language.isoenen_US
dc.relation.ispartofseriesJournal of constructional steel researchen_US
dc.rights© 2014 Elsevier Ltd. This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of Constructional Steel Research, Elsevier Ltd. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.jcsr.2014.11.002].en_US
dc.subjectDRNTU::Engineering::Civil engineering::Construction technology
dc.titleExperimental and numerical evaluation of composite floor systems under fire conditionsen_US
dc.typeJournal Article
dc.contributor.schoolSchool of Civil and Environmental Engineeringen_US
dc.identifier.doihttp://dx.doi.org/10.1016/j.jcsr.2014.11.002
dc.description.versionAccepted versionen_US
dc.identifier.rims182568


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record