dc.description.abstractThis paper carries out load profiling of Singapore housing units and office buildings using bottom-up method for peak load reduction through optimization. Housing units in Singapore are classified according to the number of rooms, ranging from one to five. Average daily, monthly and yearly electrical usage of all these units is obtained. To explore the strategies for peak load reduction, a mathematical model based on bottom-up method is created. Statistical data - hourly probability factors, frequency of daily operations, saturation levels and nominal wattage of appliances - are gathered for typical Singapore households, and load profiles are generated. The accuracy of the bottom-up model is verified by comparing the load data of a typical three-rooms housing unit in Nanyang Technological University. Then, the problem of peak load reduction is formulated into an optimization problem with peak load as cost function and hourly probability factors of certain appliances as decision vaiables. Solution to the optimal hourly probability factors is obtained using genetic algorithm and it is demonstrated through numerical simulations that about 40% reduction in peak load can be achieved. Finally, some statistical information on load estimation for office buildings is presented.en_US
dc.language.isoenen_US
dc.rights© 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [Article DOI: http://dx.doi.org/10.1109/APPEEC.2014.7065998].en_US
dc.subjectDRNTU::Engineering::Electrical and electronic engineering::Power electronics
dc.titleLoad profiling of Singapore buildings for peak shavingen_US
dc.typeConference Paper
dc.contributor.conferenceIEEE PES Asia-Pacific Power & Energy Engg. Conference–APPEEC(6th:2014:Hong Kong)en_US
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen_US
dc.identifier.doihttp://dx.doi.org/10.1109/APPEEC.2014.7065998
dc.description.versionAccepted versionen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record