dc.contributor.authorWang, Libo
dc.contributor.authorNarasimman, Srivathsan Chakaravarthi
dc.contributor.authorRavula, Sugunakar Reddy
dc.contributor.authorUkil, Abhisek
dc.date.accessioned2017-04-17T06:28:15Z
dc.date.available2017-04-17T06:28:15Z
dc.date.copyright2016
dc.date.issued2016
dc.identifier.citationWang, L., Narasimman, S. C., Ravula, S. R., & Ukil, A. (2016). Water Ingress Detection in Low-Pressure Gas Pipelines Using Distributed Temperature Sensing System. IEEE Sensors Journal, 17(10), 3165-3173.en_US
dc.identifier.issn1530-437Xen_US
dc.identifier.urihttp://hdl.handle.net/10220/42271
dc.description.abstractIn a distribution network of low-pressure gas pipelines, the situation of gas leak can be further aggravated when groundwater enters the pipeline through leaks and eventually blocks the gas flow. This will have critical implications on the gas supply to the customers. This is termed as ‘water ingress’, which typically happens only in low-pressure distribution networks, and not in high-pressure transmission networks. In order to find the location of water ingress, distributed temperature sensing (DTS) system has been used experimentally. The results show significant temperature change immediately after the onset of water ingress, and with data post-processing based on temporal difference, location information of the leak can be obtained. With a selected time window of interest, the inclination of gas pipeline is also indicated by the differenced temperature profiles. The DTS system is still capable of identifying the position, even if the location of water ingress is changed.en_US
dc.format.extent9 p.en_US
dc.language.isoenen_US
dc.relation.ispartofseriesIEEE Sensors Journalen_US
dc.rights© 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [https://doi.org/10.1109/JSEN.2017.2686982].en_US
dc.subjectDistributed network of low-pressure gas pipelineen_US
dc.subjectWater ingress detectionen_US
dc.titleWater Ingress Detection in Low-Pressure Gas Pipelines Using Distributed Temperature Sensing Systemen_US
dc.typeJournal Article
dc.contributor.researchEnergy Research Institute
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen_US
dc.identifier.doihttps://doi.org/10.1109/JSEN.2017.2686982