Title: Discussion of "assessment of the use of the vapour equilibrium technique in controlled-suction tests."
Authors: Leong, Eng Choon
He, Liangcai
Rahardjo, Harianto
Keywords: DRNTU::Engineering::Civil engineering::Geotechnical
Issue Date: 2009
Source: Leong, E. C., He, L. C., & Rahardjo, H. (2009). Discussion of “Assessment of the use of the vapour equilibrium technique in controlled-suction tests”. Canadian Geotechnical Journal, 46(12), 1482-1484.
Series/Report no.: Canadian geotechnical journal
Abstract: The authors have highlighted the possible pitfalls of the vapour equilibrium technique in controlled-suction tests using a numerical approach. Most notable is their conclusion that forcing humid air through the sample can hasten the equilibrium condition, but may result in a suction value at equilibrium different from the intended suction.
URI: https://hdl.handle.net/10356/101433
http://hdl.handle.net/10220/7317
DOI: 10.1139/T09-130
Rights: © 2009 Canadian Science Publishing
Fulltext Permission: none
Fulltext Availability: No Fulltext