Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/101033
Title: | Multi-channel deep tissue flowmetry based on temporal diffuse speckle contrast analysis | Authors: | Bi, Renzhe Dong, Jing Lee, Kijoon |
Keywords: | DRNTU::Engineering::Bioengineering | Issue Date: | 2013 | Source: | Bi, R., Dong, J., & Lee, K. (2013). Multi-channel deep tissue flowmetry based on temporal diffuse speckle contrast analysis. Optics express, 21(19), 22854-22861. | Series/Report no.: | Optics express | Abstract: | Recently, diffuse speckle contrast analysis (DSCA) was introduced as a competent modality for deep tissue blood flow measurement, where the speckle contrast is calculated over spatial domain on the CCD image of diffuse reflectance. In this paper, we introduce time-domain DSCA where temporal statistics are used for speckle contrast calculation and results in the same deep tissue flow measurement. This new modality is especially suitable for multi-channel real-time flowmetry, and we demonstrate its performance on human arm during cuff occlusion test. Independent component analysis (ICA) study on multi-channel data shows promising results about underlying physiology. | URI: | https://hdl.handle.net/10356/101033 http://hdl.handle.net/10220/18296 |
ISSN: | 1094-4087 | DOI: | 10.1364/OE.21.022854 | Schools: | School of Chemical and Biomedical Engineering | Rights: | © 2013 Optical Society of America. This paper was published in Optics Express and is made available as an electronic reprint (preprint) with permission of Optical Society of America. The paper can be found at the following official DOI: http://dx.doi.org/10.1364/OE.21.022854. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | SCBE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Multi-channel deep tissue flowmetry based on temporal diffuse speckle contrast analysis.pdf | 1.07 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
10
53
Updated on Mar 22, 2024
Web of ScienceTM
Citations
10
42
Updated on Oct 26, 2023
Page view(s) 50
509
Updated on Mar 28, 2024
Download(s) 20
326
Updated on Mar 28, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.