Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/101509
Title: | A continuous flow micro filtration device for plasma/blood separation using submicron vertical pillar gap structures | Authors: | Kang, Tae Goo Yoon, Yong-Jin Ji, Hongmiao Lim, Pei Yi Chen, Yu |
Keywords: | DRNTU::Engineering::Mechanical engineering::Mechatronics | Issue Date: | 2014 | Source: | Kang, T. G., Yoon, Y.-J., Ji, H., Lim, P. Y., & Chen, Y. (2014). A continuous flow micro filtration device for plasma/blood separation using submicron vertical pillar gap structures. Journal of micromechanics and microengineering, 24(8), 087001-. | Series/Report no.: | Journal of micromechanics and microengineering | Abstract: | This work demonstrates a continuous flow plasma/blood separator using a vertical submicron pillar gap structure. The working principle of the proposed separator is based on size exclusion of cells through cross-flow filtration, in which only plasma is allowed to pass through submicron vertical pillars located tangential to the main flow path of the blood sample. The maximum filtration efficiency of 99.9% was recorded with a plasma collection rate of 0.67 μl min−1 for an input blood flow rate of 12.5 μl min−1. The hemolysis phenomenon was observed for an input blood flow rate above 30 μl min−1. Based on the experimental results, we can conclude that the proposed device shows potential for the application of on-chip plasma/ blood separation as a part of integrated point-of-care (POC) diagnostics systems. | URI: | https://hdl.handle.net/10356/101509 http://hdl.handle.net/10220/24160 |
ISSN: | 0960-1317 | DOI: | 10.1088/0960-1317/24/8/087001 | Schools: | School of Mechanical and Aerospace Engineering | Rights: | © 2014 IOP Publishing Ltd. This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of Micromechanics and Microengineering, IOP Publishing Ltd. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [DOI: http://dx.doi.org/10.1088/0960-1317/24/8/087001]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | MAE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
jmm498481p5.pdf | 1.55 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
20
28
Updated on Apr 20, 2025
Web of ScienceTM
Citations
10
24
Updated on Oct 31, 2023
Page view(s) 10
987
Updated on May 2, 2025
Download(s) 20
320
Updated on May 2, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.