dc.identifier.citationSusanto, S., Skote, M., & Chauhan, S. (2013). In vitro assessment of combined Doppler ultrasound and CFD modeling in arterial blood flow quantification. Flow Measurement and Instrumentation, 33, 218-227.en
dc.identifier.urihttps://hdl.handle.net/10356/101615-
dc.description.abstractSpatiotemporal quantification of the blood flow in the human vasculature has been greatly aided with the non-invasive proposition offered by Doppler ultrasound. However, relatively large deviation of the blood flow measurement from the actual value is expected, owing to a number of contributing factors. The research work expounded here attempts to ameliorate the accuracy of the blood flow output quantification by combining the Doppler measurement with the computational fluid dynamics modeling based on Navier–Stokes equation. In vitro assessment of the integrated approach was carried out with custom made phantom and probe positioning Mechatronic system. Analysis of the experimental results showed that, compared to the stand alone Doppler ultrasound measurement, the integrated model gives better accuracy in quantifying the volume flow rate.en
dc.language.isoenen
dc.relation.ispartofseriesFlow measurement and instrumentationen
dc.rights© 2013 Elsevier Ltd. This is the author created version of a work that has been peer reviewed and accepted for publication by Flow Measurement and Instrumentation, Elsevier Ltd. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.flowmeasinst.2013.07.013].en
dc.subjectDRNTU::Engineering::Mechanical engineering::Mechatronicsen
dc.titleIn vitro assessment of combined Doppler ultrasound and CFD modeling in arterial blood flow quantificationen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen
dc.identifier.doi10.1016/j.flowmeasinst.2013.07.013en
dc.description.versionAccepted versionen
dc.identifier.rims175150en
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:MAE Journal Articles
Files in This Item:
File Description SizeFormat 
Swandito-Skote-Chauhan-FMI.pdf959.25 kBAdobe PDFThumbnail
View/Open

Web of ScienceTM
Citations 50

2
Updated on Mar 24, 2023

Page view(s) 50

447
Updated on Mar 29, 2023

Download(s) 20

162
Updated on Mar 29, 2023

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.