Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/101615
Title: | In vitro assessment of combined Doppler ultrasound and CFD modeling in arterial blood flow quantification | Authors: | Skote, M. Susanto, Swandito Chauhan, Sunita |
Keywords: | DRNTU::Engineering::Mechanical engineering::Mechatronics | Issue Date: | 2013 | Source: | Susanto, S., Skote, M., & Chauhan, S. (2013). In vitro assessment of combined Doppler ultrasound and CFD modeling in arterial blood flow quantification. Flow Measurement and Instrumentation, 33, 218-227. | Series/Report no.: | Flow measurement and instrumentation | Abstract: | Spatiotemporal quantification of the blood flow in the human vasculature has been greatly aided with the non-invasive proposition offered by Doppler ultrasound. However, relatively large deviation of the blood flow measurement from the actual value is expected, owing to a number of contributing factors. The research work expounded here attempts to ameliorate the accuracy of the blood flow output quantification by combining the Doppler measurement with the computational fluid dynamics modeling based on Navier–Stokes equation. In vitro assessment of the integrated approach was carried out with custom made phantom and probe positioning Mechatronic system. Analysis of the experimental results showed that, compared to the stand alone Doppler ultrasound measurement, the integrated model gives better accuracy in quantifying the volume flow rate. | URI: | https://hdl.handle.net/10356/101615 http://hdl.handle.net/10220/18711 |
DOI: | 10.1016/j.flowmeasinst.2013.07.013 | Rights: | © 2013 Elsevier Ltd. This is the author created version of a work that has been peer reviewed and accepted for publication by Flow Measurement and Instrumentation, Elsevier Ltd. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.flowmeasinst.2013.07.013]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | MAE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Swandito-Skote-Chauhan-FMI.pdf | 959.25 kB | Adobe PDF | ![]() View/Open |
Web of ScienceTM
Citations
50
2
Updated on Mar 24, 2023
Page view(s) 50
447
Updated on Mar 29, 2023
Download(s) 20
162
Updated on Mar 29, 2023
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.