Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/102604
Title: Submerged hollow fibre membrane filtration with transverse and longitudinal vibrations
Authors: Fane, Anthony Gordon
Li, Tian (CEE)
Law, Adrian Wing-Keung
Keywords: DRNTU::Engineering::Environmental engineering::Water treatment
Issue Date: 2013
Source: Li, T., Law, A. W.-K., & Fane, A. (2014). Submerged hollow fibre membrane filtration with transverse and longitudinal vibrations. Journal of Membrane Science, 455, 83-91.
Series/Report no.: Journal of membrane science
Abstract: A comparative study of transverse and longitudinal vibrations of submerged hollow fibre membranes for fouling control was carried out in this paper. The same membrane module was adopted in the comparison, and the reactor geometry was identical. The orientation between the vibration and membrane fibre directions was the only difference between the two. The feed suspensions included both inorganic Bentonite and organic yeast suspensions. The results showed that transverse vibrations were generally more effective in terms of fouling reduction even at a very low vibration frequency of 1 Hz, which may be attributed to the separating boundary layers and the associated secondary flows around the cylindrical membrane fibres. The difference between the two orientations was very substantial in Bentonite suspensions, but less so in yeast suspensions due to the main membrane foulants of cell debris in the yeast components which caused the pore blockage of the membrane. A small degree of fibre looseness was found to further improve membrane performance with transverse vibrations in both Bentonite and yeast suspensions due to additional lateral fibre movement. The effect of packing density of the membrane bundle in transverse vibrations was also examined. The results showed that at larger vibration amplitudes, a high packing density of fibres can be operated with little membrane fouling, which indicated that the secondary flow generated could overcome the strong permeate flux competition within the bundle under vibrations. Finally, vibration relaxation was tested experimentally in half-on/off switching mode with the energy reduction due directly to the 50% stoppage. The results showed that a short relaxation time interval was generally more favourable for fouling reduction.
URI: https://hdl.handle.net/10356/102604
http://hdl.handle.net/10220/18972
ISSN: 0376-7388
DOI: 10.1016/j.memsci.2013.12.042
Rights: © 2013 Elsevier B.V. This is the author created version of a work that has been peer reviewed and accepted for publication by Journal of membrane science, Elsevier B.V. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [DOI: http://dx.doi.org/10.1016/j.memsci.2013.12.042].
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:CEE Journal Articles

Files in This Item:
File Description SizeFormat 
manuscript-Submerged hollow fibre membrane filtration with transverse and longitudinal vibrations.pdfMain article609.72 kBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations

24
Updated on Sep 6, 2020

PublonsTM
Citations

23
Updated on Jan 17, 2021

Page view(s)

365
Updated on Jan 20, 2021

Download(s) 10

275
Updated on Jan 20, 2021

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.