Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/102804
Title: | Ultrahigh sensitivity refractive index sensor based on optical microfiber | Authors: | Ji, Wen Bin Liu, Huan Huan Tjin, Swee Chuan Chow, Kin Kee Lim, Anthony |
Keywords: | DRNTU::Engineering::Electrical and electronic engineering | Issue Date: | 2012 | Source: | Ji, W. B., Liu, H. H., Tjin, S. C., Chow, K. K., & Lim, A. (2012). Ultrahigh sensitivity refractive index sensor based on optical microfiber. IEEE photonics technology letters, 24(20), 1872-1874. | Series/Report no.: | IEEE photonics technology letters | Abstract: | We demonstrate a nonadiabatic microfiber sensor with a taper diameter of few micrometers. The modal interference caused by the abrupt taper results in a sinusoidal spectral response. The wavelength shift arising because of the changes in the external refractive index is found to be significant, achieving a maximum sensitivity of 18681.82 nm/RIU. The measured results show good agreement with the theoretical predictions. The high sensitivity and the simplicity offer the sensor the potential for many real applications. | URI: | https://hdl.handle.net/10356/102804 http://hdl.handle.net/10220/16421 |
ISSN: | 1041-1135 | DOI: | 10.1109/LPT.2012.2217738 | Schools: | School of Electrical and Electronic Engineering | Research Centres: | Photonics Research Centre | Rights: | © 2012 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [http://dx.doi.org/10.1109/LPT.2012.2217738]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | EEE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Ultra-high_sensitivity_refractive_index_sensor_based_on_optical_microfiber.pdf | 616.09 kB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
5
141
Updated on Mar 15, 2025
Web of ScienceTM
Citations
5
105
Updated on Oct 30, 2023
Page view(s) 20
795
Updated on Mar 20, 2025
Download(s) 5
843
Updated on Mar 20, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.