Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/103773
Full metadata record
DC FieldValueLanguage
dc.contributor.authorZeng, Shuwenen
dc.contributor.authorHu, Siyien
dc.contributor.authorXia, Jingen
dc.contributor.authorAnderson, Tommyen
dc.contributor.authorDinh, Xuan-Quyenen
dc.contributor.authorMeng, Xiang-Minen
dc.contributor.authorCoquet, Philippeen
dc.contributor.authorYong, Ken-Tyeen
dc.date.accessioned2015-01-12T01:53:19Zen
dc.date.accessioned2019-12-06T21:19:56Z-
dc.date.available2015-01-12T01:53:19Zen
dc.date.available2019-12-06T21:19:56Z-
dc.date.copyright2014en
dc.date.issued2014en
dc.identifier.citationZeng, S., Hu, S., Xia, J., Anderson, T., Dinh, X.-Q., Meng, X.-M., et al. (2015). Graphene-MoS2 hybrid nanostructures enhanced surface plasmon resonance biosensors. Sensors and Actuators B : chemical, 207, 801–810.en
dc.identifier.issn0925-4005en
dc.identifier.urihttps://hdl.handle.net/10356/103773-
dc.description.abstractIn this work, we propose a new configuration of surface plasmon resonance (SPR) sensor that is based on graphene–MoS2 hybrid structures for ultrasensitive detection of molecules. The proposed system displays a phase-sensitivity enhancement factor of more than 500-fold when compared to the SPR sensing scheme without the graphene–MoS2 coating or with only graphene coating. Our hypothesis is that the monolayer MoS2 has a much higher optical absorption efficiency (∼5%) than that of the graphene layer (∼2.3%). Based on our findings, the electron energy loss of MoS2 layer is comparable to that of graphene and this will allow a successful (∼100%) of light energy transfer to the graphene–MoS2 coated sensing substrate. Such process will lead to a significant enhancement of SPR signals. Our simulation shows that a quasi-dark point of the reflected light can be achieved under this condition and this has resulted in a steep phase jump at the resonance angle of our newly proposed SPR system. More importantly, we found that phase interrogation detection approach of the graphene–MoS2 hybrid structures-based sensing system is more sensitive than that of using the regularly angular interrogation method and our theoretical analysis indicates that 45 nm of Au film thickness and 3 coating layers of MoS2 nanosheet are the optimized parameters needed for the proposed SPR system to achieve the highest detection sensitivity range.en
dc.format.extent32 p.en
dc.language.isoenen
dc.relation.ispartofseriesSensors and Actuators B : chemicalen
dc.rights© 2014 Elsevier B.V. This is the author created version of a work that has been peer reviewed and accepted for publication by Sensors and Actuators B: Chemical, Elsevier B.V.. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [http://dx.doi.org/10.1016/j.snb.2014.10.124].en
dc.subjectDRNTU::Engineering::Electrical and electronic engineering::Electronic systems::Biometricsen
dc.titleGraphene-MoS2 hybrid nanostructures enhanced surface plasmon resonance biosensorsen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen
dc.contributor.researchResearch Techno Plazaen
dc.identifier.doi10.1016/j.snb.2014.10.124en
dc.description.versionAccepted versionen
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:EEE Journal Articles
NTC Conference Papers
Files in This Item:
File Description SizeFormat 
TMDC_Shuwen2015-new.pdf6.06 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 1

330
Updated on Jan 14, 2023

Web of ScienceTM
Citations 1

302
Updated on Jan 27, 2023

Page view(s) 5

1,122
Updated on Feb 5, 2023

Download(s) 1

1,629
Updated on Feb 5, 2023

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.