Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/104100
Title: | Double-pass Mach–Zehnder fiber interferometer pH sensor | Authors: | Tou, Zhi Qiang Chan, Chi Chiu Hong, Jesmond Png, Shermaine Tan, Eddie Khay Ming Tan, Terence Aik Huang |
Keywords: | DRNTU::Science::Medicine::Biomedical engineering DRNTU::Science::Medicine::Optical instruments |
Issue Date: | 2014 | Source: | Tou, Z. Q., Chan, C. C., Hong, J., Png, S., Tan, E. K. M., & Tan, T. A. H. (2014). Double-pass Mach–Zehnder fiber interferometer pH sensor. Journal of Biomedical Optics, 19(4), 047002-. | Series/Report no.: | Journal of biomedical optics | Abstract: | A biocompatible fiber-optic pH sensor based on a unique double-pass Mach–Zehnder interferometer is proposed. pH responsive poly(2-hydroxyethyl methacrylate-co-2-(dimethylamino)ethyl methacrylate) hydrogel coating on the fiber swells/deswells in response to local pH, leading to refractive index changes that manifest as shifting of interference dips in the optical spectrum. The pH sensor is tested in spiked phosphate buffer saline and demonstrates high sensitivity of 1.71 nm/pH , pH 0.004 limit of detection with good responsiveness, repeatability, and stability. The proposed sensor has been successfully applied in monitoring the media pH in cell culture experiments to investigate the relationship between pH and cancer cell growth. | URI: | https://hdl.handle.net/10356/104100 http://hdl.handle.net/10220/19524 |
ISSN: | 1083-3668 | DOI: | 10.1117/1.JBO.19.4.047002 | Schools: | School of Chemical and Biomedical Engineering | Rights: | © 2014 Society of Photo-Optical Instrumentation Engineers. This paper was published in Journal of Biomedical Optics and is made available as an electronic reprint (preprint) with permission of Society of Photo-Optical Instrumentation Engineers. The paper can be found at the following official DOI: http://dx.doi.org/10.1117/1.JBO.19.4.047002. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | SCBE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Double-pass Mach–Zehnder fiber interferometer pH sensor.pdf | 1.58 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
20
15
Updated on Mar 2, 2024
Web of ScienceTM
Citations
20
14
Updated on Oct 25, 2023
Page view(s) 20
662
Updated on Mar 18, 2024
Download(s) 10
353
Updated on Mar 18, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.