Title: Double-pass Mach–Zehnder fiber interferometer pH sensor
Authors: Tou, Zhi Qiang
Chan, Chi Chiu
Hong, Jesmond
Png, Shermaine
Tan, Eddie Khay Ming
Tan, Terence Aik Huang
Keywords: DRNTU::Science::Medicine::Biomedical engineering
DRNTU::Science::Medicine::Optical instruments
Issue Date: 2014
Source: Tou, Z. Q., Chan, C. C., Hong, J., Png, S., Tan, E. K. M., & Tan, T. A. H. (2014). Double-pass Mach–Zehnder fiber interferometer pH sensor. Journal of Biomedical Optics, 19(4), 047002-.
Series/Report no.: Journal of biomedical optics
Abstract: A biocompatible fiber-optic pH sensor based on a unique double-pass Mach–Zehnder interferometer is proposed. pH responsive poly(2-hydroxyethyl methacrylate-co-2-(dimethylamino)ethyl methacrylate) hydrogel coating on the fiber swells/deswells in response to local pH, leading to refractive index changes that manifest as shifting of interference dips in the optical spectrum. The pH sensor is tested in spiked phosphate buffer saline and demonstrates high sensitivity of 1.71  nm/pH , pH 0.004 limit of detection with good responsiveness, repeatability, and stability. The proposed sensor has been successfully applied in monitoring the media pH in cell culture experiments to investigate the relationship between pH and cancer cell growth.
URI: https://hdl.handle.net/10356/104100
http://hdl.handle.net/10220/19524
ISSN: 1083-3668
DOI: 10.1117/1.JBO.19.4.047002
Schools: School of Chemical and Biomedical Engineering 
Rights: © 2014 Society of Photo-Optical Instrumentation Engineers. This paper was published in Journal of Biomedical Optics and is made available as an electronic reprint (preprint) with permission of Society of Photo-Optical Instrumentation Engineers. The paper can be found at the following official DOI: http://dx.doi.org/10.1117/1.JBO.19.4.047002.  One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law.
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:SCBE Journal Articles

Files in This Item:
File Description SizeFormat 
Double-pass Mach–Zehnder fiber interferometer pH sensor.pdf1.58 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 20

15
Updated on Mar 2, 2024

Web of ScienceTM
Citations 20

14
Updated on Oct 25, 2023

Page view(s) 20

662
Updated on Mar 18, 2024

Download(s) 10

353
Updated on Mar 18, 2024

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.