Title: | Disturbance detection in the MV and the LV distribution networks using time-domain method | Authors: | Ukil, Abhisek | Keywords: | DRNTU::Engineering::Electrical and electronic engineering | Issue Date: | 2014 | Source: | Ukil, A. (2014). Disturbance detection in the MV and the LV distribution networks using time-domain method. IEEE Power & Energy Society General Meeting (2014: National Harbor MD, USA), 1-5. | Conference: | IEEE Power & Energy Society General Meeting (2014: National Harbor MD, USA) | Abstract: | With the growing need for disturbance-free power distribution, there has been significant focus under the ‘Smart Grid’ initiative on fault and disturbance analysis. Compared to the high voltage (HV) transmission systems where high-end relays can be used, medium- and low-voltage (MV, LV) distribution systems employ low-end relays for cost reason. Therefore, computationally inexpensive signal processing algorithms are needed for disturbance identification at the MV and the LV distribution systems. In this paper, a novel amplitude tracking square wave concept is presented, which can effectively represent the complex sinusoidal signals under disturbance. The amplitude tracking square wave is very sensitive to any degradation introduced in the sinusoidal signals due to disturbances. These are typically reflected in the time-domain as spikes in the square wave, without requiring any frequency analysis. This makes it particularly attractive for embedding into the MV and the LV relays with limited computational resources. Successful application of the algorithm on real disturbance records substantiate its potential. | URI: | https://hdl.handle.net/10356/105070 http://hdl.handle.net/10220/20397 |
URL: | http://www.researchgate.net/publication/264250683_Disturbance_Detection_in_the_MV_and_the_LV_Distribution_Networks_Using_Time-Domain_Method | Schools: | School of Electrical and Electronic Engineering | Rights: | © 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [Article URL: http://www.researchgate.net/publication/264250683_Disturbance_Detection_in_the_MV_and_the_LV_Distribution_Networks_Using_Time-Domain_Method]. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | EEE Conference Papers |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Disturbance Detection in the MV and the LV.pdf | 214.9 kB | Adobe PDF | ![]() View/Open |
Page view(s) 50
584
Updated on May 7, 2025
Download(s) 20
293
Updated on May 7, 2025
Google ScholarTM
Check
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.