Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/106029
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bo, En | en |
dc.contributor.author | Wang, Lulu | en |
dc.contributor.author | Xie, Jun | en |
dc.contributor.author | Ge, Xin | en |
dc.contributor.author | Liu, Linbo | en |
dc.date.accessioned | 2019-08-07T03:06:08Z | en |
dc.date.accessioned | 2019-12-06T22:03:10Z | - |
dc.date.available | 2019-08-07T03:06:08Z | en |
dc.date.available | 2019-12-06T22:03:10Z | - |
dc.date.issued | 2018 | en |
dc.identifier.citation | Bo, E., Wang, L., Xie, J., Ge, X., & Liu, L. (2018). Pixel-reassigned spectral-domain optical coherence tomography. IEEE Photonics Journal, 10(2), 3900408-. doi:10.1109/JPHOT.2018.2813523 | en |
dc.identifier.issn | 1943-0655 | en |
dc.identifier.uri | https://hdl.handle.net/10356/106029 | - |
dc.description.abstract | A novel method of pixel reassignment (PRA) is proposed to achieve transverse superresolution in the confocal microscopy. Inspired by it, for the first time, we report a pixel-reassigned spectral-domain optical coherence tomography (OCT) with ~1.5 times transverse resolution improvement both in numerical simulations and imaging experiments. PRA is implemented by transversely shifting the detection fiber from the on-axis position to five off-axis positions, capturing cross-sectional images at each shifting step of the detection fiber and digitally reassigning them together to give a sharper image with moderately extended depth of focus and enhanced intensity. So, we believe that the PRA technique will improve the imaging performance and be beneficial to the development of the OCT community. | en |
dc.description.sponsorship | NRF (Natl Research Foundation, S’pore) | en |
dc.description.sponsorship | MOE (Min. of Education, S’pore) | en |
dc.description.sponsorship | NMRC (Natl Medical Research Council, S’pore) | en |
dc.format.extent | 8 p. | en |
dc.language.iso | en | en |
dc.relation.ispartofseries | IEEE Photonics Journal | en |
dc.rights | © 2017 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information. | en |
dc.subject | Coherent Imaging | en |
dc.subject | Optical Coherence Tomography (OCT) | en |
dc.subject | Engineering::Electrical and electronic engineering | en |
dc.title | Pixel-reassigned spectral-domain optical coherence tomography | en |
dc.type | Journal Article | en |
dc.contributor.school | School of Chemical and Biomedical Engineering | en |
dc.contributor.school | School of Electrical and Electronic Engineering | en |
dc.identifier.doi | 10.1109/JPHOT.2018.2813523 | en |
dc.description.version | Published version | en |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
Appears in Collections: | EEE Journal Articles SCBE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Pixel-reassigned spectral-domain optical coherence tomography.pdf | 512.35 kB | Adobe PDF | View/Open |
SCOPUSTM
Citations
50
2
Updated on Mar 28, 2024
Web of ScienceTM
Citations
50
2
Updated on Oct 30, 2023
Page view(s)
346
Updated on Mar 28, 2024
Download(s) 50
74
Updated on Mar 28, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.