Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/106385
Title: Photoacoustic imaging depth comparison at 532-, 800-, and 1064-nm wavelengths : Monte Carlo simulation and experimental validation
Authors: Sharma, Arunima
Srishti
Periyasamy, Vijitha
Pramanik, Manojit
Keywords: Photoacoustic Imaging
Photoacoustic Tomography
Engineering::Chemical engineering
Issue Date: 2019
Source: Sharma, A., Srishti, Periyasamy, V., & Pramanik, M. (2019). Photoacoustic imaging depth comparison at 532-, 800-, and 1064-nm wavelengths : Monte Carlo simulation and experimental validation. Journal of Biomedical Optics, 24(12), 1-. doi:10.1117/1.JBO.24.12.121904
Series/Report no.: Journal of Biomedical Optics
Abstract: Photoacoustic imaging (PAI) provides high-resolution and high-optical-contrast imaging beyond optical diffusion limit. Further improvement in imaging depth has been achieved by using near-infrared window-I (NIR-I, 700 to 900 nm) for illumination, due to lower scattering and absorption by tissues in this wavelength range. Recently, near-infrared window-II (NIR-II, 900 to 1700 nm) has been explored for PAI. We studied the imaging depths in biological tissues for different illumination wavelengths in visible, NIR-I, and NIR-II regions using Monte Carlo (MC) simulations and validated with experimental results. MC simulations were done to compute fluence in tissue, absorbance in blood vessel, and in a spherical absorber (mimicking sentinel lymph node) embedded at different depths in breast tissue. Photoacoustic tomography and acoustic resolution photoacoustic microscopy experiments were conducted to validate the MC results. We demonstrate that maximum imaging depth is achieved by wavelengths in NIR-I window (∼800  nm) when the energy density deposited is same for all wavelengths. However, illumination using wavelengths around 1064 nm (NIR-II window) gives the maximum imaging depth when the energy density deposited is proportional to maximum permissible exposure (MPE) at corresponding wavelength. These results show that it is the higher MPE of NIR-II window that helps in increasing the PAI depth for chromophores embedded in breast tissue.
URI: https://hdl.handle.net/10356/106385
http://hdl.handle.net/10220/49593
ISSN: 1083-3668
DOI: 10.1117/1.JBO.24.12.121904
Rights: © 2019 The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:SCBE Journal Articles

Google ScholarTM

Check

Altmetric

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.