Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/106648
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLim, Yee Yanen
dc.contributor.authorSoh, Chee Kiongen
dc.date.accessioned2015-02-02T02:11:24Zen
dc.date.accessioned2019-12-06T22:15:39Z-
dc.date.available2015-02-02T02:11:24Zen
dc.date.available2019-12-06T22:15:39Z-
dc.date.copyright2014en
dc.date.issued2014en
dc.identifier.citationLim, Y. Y., & Soh, C. K. (2014). Electro-mechanical impedance (EMI)-based incipient crack monitoring and critical crack identification of beam structures. Research in nondestructive evaluation, 25(2), 82-98.en
dc.identifier.issn0934-9847en
dc.identifier.urihttps://hdl.handle.net/10356/106648-
dc.description.abstractFatigue-induced damage is often progressive and gradual in nature. Fatigue is often deteriorated by corrosion in ageing structures, creating maintenance problems, and even causing catastrophic failure. This ushers the development of structural health monitoring (SHM) and nondestructive evaluation (NDE) systems. Recent advent of smart materials applicable in SHM alleviates the shortcomings of the conventional techniques. Autonomous, real-time, remote monitoring becomes possible with the use of smart piezoelectric transducers. For instance, the electro-mechanical impedance (EMI) technique, employing piezoelectric transducers as collocated actuators and sensors, is known for its ability in damage detection and characterization. This article presents a series of lab-scale experimental tests and analysis to investigate the feasibility of fatigue crack detection and characterization employing the EMI technique. This study extends the work by Lim and Soh [1] to incorporate the phases involving crack initiation and critical crack. It is suggested that the EMI technique is effective in characterizing fatigue induced cracking, even in its incipient stage. Micro-crack invisible to the naked eyes can be detected by the technique especially when employing the higher frequency range of 100–200 kHz. A quick and handy qualitative-based critical crack identification method is also suggested by visually inspecting the admittance frequency spectrum.en
dc.language.isoenen
dc.relation.ispartofseriesResearch in nondestructive evaluationen
dc.rights© 2014 American Society for Nondestructive Testing. This paper was published in Research in Nondestructive Evaluation and is made available as an electronic reprint (preprint) with permission of American Society for Nondestructive Testing. The paper can be found at the following official DOI: [http://dx.doi.org/10.1080/09349847.2013.848311].  One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law."en
dc.subjectDRNTU::Engineering::Civil engineering::Construction technologyen
dc.titleElectro-mechanical impedance (EMI)-based incipient crack monitoring and critical crack identification of beam structuresen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Civil and Environmental Engineeringen
dc.identifier.doi10.1080/09349847.2013.848311en
dc.description.versionPublished versionen
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:CEE Journal Articles
Files in This Item:
File Description SizeFormat 
09349847%2E2013%2E848311.pdf1.38 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 20

59
Updated on Apr 19, 2025

Web of ScienceTM
Citations 10

45
Updated on Oct 25, 2023

Page view(s) 50

511
Updated on Apr 20, 2025

Download(s) 10

630
Updated on Apr 20, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.