Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/106670
Title: | Single input state polarization-sensitive optical coherence tomography with high resolution and polarization distortion correction | Authors: | Xiong, Qiaozhou Wang, Nanshuo Liu, Xinyu Chen, Si Liang, Haitao Chen, Shufen Liu, Linbo |
Keywords: | Optic Nerve Engineering::Electrical and electronic engineering Circular Polarization |
Issue Date: | 2019 | Source: | Xiong, Q., Wang, N., Liu, X., Chen, S., Liang, H., Chen, S., & Liu, L. (2019). Single input state polarization-sensitive optical coherence tomography with high resolution and polarization distortion correction. Optics Express, 27(5), 6910-6924. doi:10.1364/OE.27.006910 | Series/Report no.: | Optics Express | Abstract: | Abstract: In single input state polarization-sensitive optical coherence tomography (PS-OCT) with high resolution, the imperfections of quarter-wave plate (QWP) and the sensitivity roll-off mismatch between the two detection channels cause unpredictable polarization distortion. We present a correction method based on the Jones matrix modeling of the system. In a single input PS-OCT system working at 840 nm with an axial resolution of ~2.3 μm, the method yielded better estimation of retardation and optic axis orientation with significantly reduced noise level, especially in weakly birefringent samples. Numerical simulations and quantitative imaging of a sample of known birefringence were performed to validate the performance. We further demonstrate the advantages of our approach with birefringence imaging of swine retina, rat aortic wall, and rat esophageal mucosa for potential clinical applications. | URI: | https://hdl.handle.net/10356/106670 http://hdl.handle.net/10220/49648 |
ISSN: | 1094-4087 | DOI: | 10.1364/OE.27.006910 | Schools: | School of Chemical and Biomedical Engineering School of Electrical and Electronic Engineering |
Rights: | © 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement. Users may use, reuse, and build upon the article, or use the article for text or data mining, so long as such uses are for non-commercial purposes and appropriate attribution is maintained. All other rights are reserved. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | EEE Journal Articles SCBE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Single input state polarization-sensitive optical coherence tomography with high resolution and polarization distortion correction.pdf | 7.83 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
20
13
Updated on May 6, 2025
Web of ScienceTM
Citations
20
10
Updated on Oct 30, 2023
Page view(s) 20
836
Updated on May 7, 2025
Download(s) 50
122
Updated on May 7, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.