Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/107088
Title: A statistic-based calibration method for TIADC system
Authors: Yang, Kuojun
Tian, Shulin
Ye, Peng
Zhang, Peng
Zheng, Yuanjin
Keywords: DRNTU::Engineering::Mathematics and analysis
Issue Date: 2015
Source: Yang, K., Tian, S., Ye, P., Zhang, P., & Zheng, Y. (2015). A statistic-based calibration method for TIADC system. Mathematical problems in engineering, 2015, 1-9.
Series/Report no.: Mathematical problems in engineering
Abstract: Time-interleaved technique is widely used to increase the sampling rate of analog-to-digital converter (ADC). However, the channel mismatches degrade the performance of time-interleaved ADC (TIADC). Therefore, a statistic-based calibration method for TIADC is proposed in this paper. The average value of sampling points is utilized to calculate offset error, and the summation of sampling points is used to calculate gain error. After offset and gain error are obtained, they are calibrated by offset and gain adjustment elements in ADC. Timing skew is calibrated by an iterative method. The product of sampling points of two adjacent subchannels is used as a metric for calibration. The proposed method is employed to calibrate mismatches in a four-channel 5 GS/s TIADC system. Simulation results show that the proposed method can estimate mismatches accurately in a wide frequency range. It is also proved that an accurate estimation can be obtained even if the signal noise ratio (SNR) of input signal is 20 dB. Furthermore, the results obtained from a real four-channel 5 GS/s TIADC system demonstrate the effectiveness of the proposed method. We can see that the spectra spurs due to mismatches have been effectively eliminated after calibration.
URI: https://hdl.handle.net/10356/107088
http://hdl.handle.net/10220/25355
DOI: 10.1155/2015/689869
Schools: School of Electrical and Electronic Engineering 
Rights: © 2015 Kuojun Yang et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:EEE Journal Articles

Files in This Item:
File Description SizeFormat 
A Statistic-Based Calibration Method for TIADC System.pdf2.78 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 50

8
Updated on Apr 21, 2025

Web of ScienceTM
Citations 50

4
Updated on Oct 24, 2023

Page view(s) 50

649
Updated on May 7, 2025

Download(s) 20

307
Updated on May 7, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.