Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/107088
Title: | A statistic-based calibration method for TIADC system | Authors: | Yang, Kuojun Tian, Shulin Ye, Peng Zhang, Peng Zheng, Yuanjin |
Keywords: | DRNTU::Engineering::Mathematics and analysis | Issue Date: | 2015 | Source: | Yang, K., Tian, S., Ye, P., Zhang, P., & Zheng, Y. (2015). A statistic-based calibration method for TIADC system. Mathematical problems in engineering, 2015, 1-9. | Series/Report no.: | Mathematical problems in engineering | Abstract: | Time-interleaved technique is widely used to increase the sampling rate of analog-to-digital converter (ADC). However, the channel mismatches degrade the performance of time-interleaved ADC (TIADC). Therefore, a statistic-based calibration method for TIADC is proposed in this paper. The average value of sampling points is utilized to calculate offset error, and the summation of sampling points is used to calculate gain error. After offset and gain error are obtained, they are calibrated by offset and gain adjustment elements in ADC. Timing skew is calibrated by an iterative method. The product of sampling points of two adjacent subchannels is used as a metric for calibration. The proposed method is employed to calibrate mismatches in a four-channel 5 GS/s TIADC system. Simulation results show that the proposed method can estimate mismatches accurately in a wide frequency range. It is also proved that an accurate estimation can be obtained even if the signal noise ratio (SNR) of input signal is 20 dB. Furthermore, the results obtained from a real four-channel 5 GS/s TIADC system demonstrate the effectiveness of the proposed method. We can see that the spectra spurs due to mismatches have been effectively eliminated after calibration. | URI: | https://hdl.handle.net/10356/107088 http://hdl.handle.net/10220/25355 |
DOI: | 10.1155/2015/689869 | Schools: | School of Electrical and Electronic Engineering | Rights: | © 2015 Kuojun Yang et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | EEE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
A Statistic-Based Calibration Method for TIADC System.pdf | 2.78 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
50
8
Updated on Apr 21, 2025
Web of ScienceTM
Citations
50
4
Updated on Oct 24, 2023
Page view(s) 50
649
Updated on May 7, 2025
Download(s) 20
307
Updated on May 7, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.