Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/107205
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLi, Bingen
dc.contributor.authorQian, Kaien
dc.date.accessioned2015-04-10T03:38:11Zen
dc.date.accessioned2019-12-06T22:26:38Z-
dc.date.available2015-04-10T03:38:11Zen
dc.date.available2019-12-06T22:26:38Z-
dc.date.copyright2015en
dc.date.issued2015en
dc.identifier.citationQian, K. & Li, B. (2015). Load-resisting mechanism to mitigate progressive collapse of flat slab structures. Magazine of concrete research, 67(7), 349-363.en
dc.identifier.urihttps://hdl.handle.net/10356/107205-
dc.description.abstractFor reinforced concrete flat slab structures, column failure due to unexpected extreme loading may significantly increase the moment and shear force at adjacent slab–column connections, which can trigger punching shear failure at these connections and result in progressive collapse of flat slab structures. To determine the possible load-resisting mechanisms developed in flat slab structures in resisting progressive collapse, three multi-panel flat slab substructures are tested in this study. A flat slab substructure is tested as a control specimen. The remaining two specimens are strengthened by adding drop panels or post-installed shear bolts. Punching shear failure is observed in the control specimen and the specimen with post-installed shear bolts after reaching their yield loads. However, even the control specimen without any strengthening exhibited considerable post-failure resistance and deformation capacity mainly due to sufficient integrity reinforcement, which had been installed in the bottom of the slab. Test results indicated that drop panels not only increase the flexural resistance but also raise the punching shear resistance of the connections significantly. Thus, no obvious punching shear failure is observed in the specimen with drop panels. However, post-installed shear bolts can only increase the punching shear resistance. For post-failure behaviour, this is not very effective. The test results demonstrated that flexural failure dominates the performance of test specimens, as relatively low slab reinforcement ratio but high span/thickness ratio was designed.en
dc.format.extent15 p.en
dc.language.isoenen
dc.relation.ispartofseriesMagazine of concrete researchen
dc.rights© 2015 Thomas Telford Ltd. This paper was published in Magazine of Concrete Research and is made available as an electronic reprint (preprint) with permission of Thomas Telford Ltd. The paper can be found at the following official DOI: [http://dx.doi.org/10.1680/macr.14.00293].  One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law.en
dc.subjectDRNTU::Engineering::Civil engineering::Structures and designen
dc.titleLoad-resisting mechanism to mitigate progressive collapse of flat slab structuresen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Civil and Environmental Engineeringen
dc.identifier.doi10.1680/macr.14.00293en
dc.description.versionPublished versionen
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:CEE Journal Articles
Files in This Item:
File Description SizeFormat 
Load-resisting mechanism to mitigate progressive collapse of flat slab structures.pdf2.57 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 10

67
Updated on Apr 14, 2025

Web of ScienceTM
Citations 10

47
Updated on Oct 25, 2023

Page view(s) 20

724
Updated on Apr 17, 2025

Download(s) 5

759
Updated on Apr 17, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.