Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/107381
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSoh, Cheong Boonen
dc.contributor.authorGunawan, Erryen
dc.contributor.authorLow, Kay-Soonen
dc.contributor.authorThomas, Rijilen
dc.contributor.authorQi, Yongbinen
dc.date.accessioned2015-05-18T02:44:54Zen
dc.date.accessioned2019-12-06T22:29:42Z-
dc.date.available2015-05-18T02:44:54Zen
dc.date.available2019-12-06T22:29:42Z-
dc.date.copyright2015en
dc.date.issued2015en
dc.identifier.citationQi, Y., Soh, C., Gunawan, E., Low, K.-S., & Thomas, R. (2015). Lower extremity joint angle tracking with wireless ultrasonic sensors during a squat exercise. Sensors, 15(5), 9610-9627.en
dc.identifier.issn1424-8220en
dc.identifier.urihttps://hdl.handle.net/10356/107381-
dc.description.abstractThis paper presents an unrestrained measurement system based on a wearable wireless ultrasonic sensor network to track the lower extremity joint and trunk kinematics during a squat exercise with only one ultrasonic sensor attached to the trunk. The system consists of an ultrasound transmitter (mobile) and multiple receivers (anchors) whose positions are known. The proposed system measures the horizontal and vertical displacement, together with known joint constraints, to estimate joint flexion/extension angles using an inverse kinematic model based on the damped least-squares technique. The performance of the proposed ultrasonic measurement system was validated against a camera-based tracking system on eight healthy subjects performing a planar squat exercise. Joint angles estimated from the ultrasonic system showed a root mean square error (RMSE) of 2.85° ± 0.57° with the reference system. Statistical analysis indicated great agreements between these two systems with a Pearson’s correlation coefficient (PCC) value larger than 0.99 for all joint angles’ estimation. These results show that the proposed ultrasonic measurement system is useful for applications, such as rehabilitation and sports.en
dc.format.extent18 p.en
dc.language.isoenen
dc.relation.ispartofseriesSensorsen
dc.rights© 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).en
dc.subjectDRNTU::Engineering::Electrical and electronic engineeringen
dc.titleLower extremity joint angle tracking with wireless ultrasonic sensors during a squat exerciseen
dc.typeJournal Articleen
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen
dc.identifier.doi10.3390/s150509610en
dc.description.versionPublished versionen
dc.identifier.pmid25915589-
item.fulltextWith Fulltext-
item.grantfulltextopen-
Appears in Collections:EEE Journal Articles

SCOPUSTM   
Citations 20

13
Updated on Nov 25, 2022

Web of ScienceTM
Citations 20

10
Updated on Nov 27, 2022

Page view(s) 50

468
Updated on Dec 1, 2022

Download(s) 20

209
Updated on Dec 1, 2022

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.