Title: Effect of hydraulic retention time on membrane bioreactor system with prolonged sludge retention time
Authors: Zeng, Luhai
Keywords: DRNTU::Engineering::Environmental engineering::Water treatment
Issue Date: 2003
Abstract: A study on the effect of hydraulic retention time on membrane bioreactor system with prolonged sludge retention time was carried out. A submerged tubular ceramic membrane bioreactor (MBR) in laboratory scale, with a prolonged sludge retention time (SRT) of 200 days, was applied to reduce substantially the amount of disposed sludge. The MBR system was operated for 6 Runs, differentiated by hydraulic retention time (HRT).
URI: http://hdl.handle.net/10356/12163
Schools: School of Civil and Environmental Engineering 
Rights: Nanyang Technological University
Fulltext Permission: restricted
Fulltext Availability: With Fulltext