Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/137786
Title: | Fluorescence-based immunosensor using three-dimensional CNT network structure for sensitive and reproducible detection of oral squamous cell carcinoma biomarker | Authors: | Song, Chung Kil Oh, Eunkyul Kang, Min Sung Shin, Bum Seok Han, Soo Young Jung, Mingi Lee, Eui Seok Yoon, Soo-Young Sung, Myung Mo Ng, Wei Beng Cho, Nam-Joon Lee, Haiwon |
Keywords: | Engineering::Materials | Issue Date: | 2018 | Source: | Song, C. K., Oh, E., Kang, M. S., Shin, B. S., Han, S. Y., Jung, M., . . . Lee, H. (2018). Fluorescence-based immunosensor using three-dimensional CNT network structure for sensitive and reproducible detection of oral squamous cell carcinoma biomarker. Analytica Chimica Acta, 1027, 101-108. doi:10.1016/j.aca.2018.04.025 | Journal: | Analytica Chimica Acta | Abstract: | A hierarchical three-dimensional network of carbon nanotubes on Si pillar substrate (3DN-CNTs) was developed for the accurate detection of oral squamous cell carcinoma (OSCC) in clinical saliva samples. The 3DN-CNTs were uniformly coated with a layer of aluminum oxides to enhance structural stability during biomarker detection. Cytokeratin-19 antigen (Cyfra 21-1) was utilized as a model biomarker of OSCC for fluorescence-based immunosensor using 3DN-CNTs (3DN-CNTs sensor). The 3DN-CNTs sensor enhances the sensitivity of Cyfra 21-1 detection by increasing the density of immobilized antibody through high surface area of 3DN-CNTs and enhancing the accessibility of biomolecules through the ordered pathway of hierarchical structure. The reliable detection limit for sensing of Cyfra 21-1 was estimated as in the level of 0.5 ng/mL and the quantitative estimation of Cyfra 21-1 was analyzed by 4-parameter logistic (4-PL) model for curve-fitting analysis. Clinical applicability of 3DN-CNTs sensor was evaluated through correlation with the commercially available electrochemiluminescence (ECL) detection system in the hospital. The assay results of the two systems for clinical saliva samples showed a good linear correlation. The 3DN-CNTs sensor offers great potential for accurate diagnosis of OSCC using Cyfra 21-1 biomarker in clinical fluids. | URI: | https://hdl.handle.net/10356/137786 | ISSN: | 0003-2670 | DOI: | 10.1016/j.aca.2018.04.025 | Rights: | © 2018 Elsevier B.V. All rights reserved. | Fulltext Permission: | none | Fulltext Availability: | No Fulltext |
Appears in Collections: | MSE Journal Articles |
SCOPUSTM
Citations
20
12
Updated on Mar 10, 2021
PublonsTM
Citations
20
11
Updated on Mar 9, 2021
Page view(s)
142
Updated on May 18, 2022
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.