Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/137809
Title: Heterogeneous strain distribution of elastomer substrates to enhance the sensitivity of stretchable strain sensors
Authors: Jiang, Ying
Liu, Zhiyuan
Wang, Changxian
Chen, Xiaodong
Keywords: Engineering::Materials
Issue Date: 2019
Source: Jiang, Y., Liu, Z., Wang, C., & Chen, X. (2019). Heterogeneous strain distribution of elastomer substrates to enhance the sensitivity of stretchable strain sensors. Accounts of Chemical Research, 52(1), 82-90. doi:10.1021/acs.accounts.8b00499
Journal: Accounts of Chemical Research 
Abstract: Stretchable strain sensors, which convert mechanical stimuli into electrical signals, largely fuel the growth of wearable bioelectronics due to the ubiquitous, health-related strain in biological systems. In contrast to rigid conventional strain sensors, stretchable strain sensors present advantages of conformality and stretchability, solving the mechanical mismatch between electronics and the human body. However, the great challenge of stretchable strain sensors lies in achieving high sensitivity, which is required for both signal fidelity and cost considerations. Recent advances to solve this sensitivity challenge have focused on material optimization, in search of the optimum combination of conductive active materials and elastomer substrates among a myriad of artificial or natural materials. However, high sensitivity with a gauge factor larger than 50 remains a grand challenge, especially within large-strain regions.Here we present heterogeneous strain distribution of elastomer substrates as a powerful strategy to significantly enhance the sensitivity of stretchable strain sensors. The theoretical foundation of this strategy is mathematically proven on the basis of Ohm’s law in electrics and mechanics of materials. First, the extent of the sensitivity enhancement is proved to be determined by the local strain in resistance-testing segments of heterogeneous strain sensors. Next, the local strain is proved to be quantitatively decided by material properties such as section area and Young’s modulus. Thus, the necessary and sufficient condition to achieve high sensitivity in heterogeneous strain sensors is that the Young’s modulus reciprocal or section area reciprocal in the resistance-testing segment is larger than the mean value. This provides a theoretical design guideline to achieve high sensitivity via heterogeneous strain distribution. On the basis of this guideline, we systematically summarize concrete instances of heterogeneity-induced sensitivity improvement in stretchable strain sensors, in sequence of increasing dimensionality. A typical example of a one-dimensional heterogeneous strain sensor is a structured fiber with microbeads, where the varied section area along the fiber axis results in heterogeneous strain and sensitivity improvement. Two-dimensional heterogeneous sensors in the form of thin films contain thickness gradient sensors and auxetic mechanical metamaterial sensors. The former exhibit heterogeneous section area via the self-pinning method, while the latter show heterogeneity in both the strain direction and amplitude, leading to a 24-fold improvement in sensitivity. Three-dimensional strain sensors include rationally structured sensors for out-of-plane force detection and asymmetric active materials in electronic whiskers. The resultant enhanced sensitivity in these heterogeneous strain sensors is beneficial for applications such as continuous health monitoring, biomedical diagnostics, and replacement prosthetics, taking advantage of augmented detection accuracy and declined device cost. Finally, we discuss possible future work in exploiting heterogeneous strain distributions, involving extended methodology to achieve heterogeneity, employing suppressed strain for stretchable electrodes, cyclic durability for long-term applications, and multifunctional system-level integration. We believe that this strategy of using heterogeneous strain distribution to enhance sensitivity can strongly promote the development of stretchable strain sensors for both practical and theoretical requirements.
URI: https://hdl.handle.net/10356/137809
ISSN: 0001-4842
DOI: 10.1021/acs.accounts.8b00499
Schools: School of Materials Science & Engineering 
Organisations: Innovative Centre for Flexible Devices (iFLEX) 
Rights: This document is the Accepted Manuscript version of a Published Work that appeared in final form in Accounts of Chemical Research, copyright © American Chemical Society after peer review and technical editing by the publisher. To access the final edited and published work see https://doi.org/10.1021/acs.accounts.8b00499
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:MSE Journal Articles

Files in This Item:
File Description SizeFormat 
1. Heterogeneous strain distribution.pdf731.88 kBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 10

63
Updated on May 5, 2025

Web of ScienceTM
Citations 10

45
Updated on Oct 24, 2023

Page view(s) 50

573
Updated on May 5, 2025

Download(s) 10

557
Updated on May 5, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.