Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/137856
Title: Force sensing with 1 mm fiber Bragg gratings for flexible endoscopic surgical robots
Authors: Lai, Wenjie
Cao, Lin
Tan, Rex Xiao
Phan, Phuoc Thien
Hao, Jianzhong
Tjin, Swee Chuan
Phee, Soo Jay
Keywords: Engineering::Mechanical engineering::Robots
Issue Date: 2019
Source: Lai, W., Cao, L., Tan, R. X., Phan, P. T., Hao, J., Tjin, S. C., & Phee, S. J. (2020). Force sensing with 1 mm fiber Bragg gratings for flexible endoscopic surgical robots. IEEE/ASME Transactions on Mechatronics, 25(1), 371-382. doi:10.1109/tmech.2019.2951540
Journal: IEEE/ASME Transactions on Mechatronics
Abstract: This article presents a novel force sensor to detect the distal force of tendon-sheath mechanisms (TSMs) in flexible endoscopic surgical robots. We propose to measure the compression force on the sheath at the distal end so that the tension force on the tendon, which equals the compression force on the sheath, can be obtained. With this approach, a new force sensor made up of a 1 mm fiber Bragg grating attached to a 3 mm long nitinol tube was developed to measure the compression force exerted on the sheath. Mechanics analysis and verification tests were conducted to characterize the relationship between tension and compression on a TSM. Force calibrations, hysteresis study, and temperature compensation verification tests on the sensor were carried out. The force sensor has a measurement error of 0.178 N and a sensitivity of 34.14 pm/N. Applications of the sensor in a TSM-driven robotic grasper and a tendon-driven continuum robot were demonstrated. This force sensor has salient advantages: it is small, structurally simple, electrically passive, temperature-compensated, easy to assemble and disassemble, flexible, and biocompatible. This proposed approach with the new force sensor can also be applied to both TSM-driven systems and tendon-driven systems such as robotic fingers/hands, wearable devices, surgical catheters, and rehabilitation devices.
URI: https://hdl.handle.net/10356/137856
ISSN: 1941-014X
DOI: 10.1109/TMECH.2019.2951540
Rights: © 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: https://doi.org/10.1109/TMECH.2019.2951540
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:MAE Journal Articles

Files in This Item:
File Description SizeFormat 
Tmech_WJ final.pdf1.91 MBAdobe PDFView/Open

SCOPUSTM   
Citations 20

21
Updated on Jan 29, 2023

Web of ScienceTM
Citations 10

23
Updated on Feb 2, 2023

Page view(s)

223
Updated on Feb 4, 2023

Download(s) 20

180
Updated on Feb 4, 2023

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.