Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/137856
Title: | Force sensing with 1 mm fiber Bragg gratings for flexible endoscopic surgical robots | Authors: | Lai, Wenjie Cao, Lin Tan, Rex Xiao Phan, Phuoc Thien Hao, Jianzhong Tjin, Swee Chuan Phee, Soo Jay |
Keywords: | Engineering::Mechanical engineering::Robots | Issue Date: | 2019 | Source: | Lai, W., Cao, L., Tan, R. X., Phan, P. T., Hao, J., Tjin, S. C., & Phee, S. J. (2020). Force sensing with 1 mm fiber Bragg gratings for flexible endoscopic surgical robots. IEEE/ASME Transactions on Mechatronics, 25(1), 371-382. doi:10.1109/tmech.2019.2951540 | Journal: | IEEE/ASME Transactions on Mechatronics | Abstract: | This article presents a novel force sensor to detect the distal force of tendon-sheath mechanisms (TSMs) in flexible endoscopic surgical robots. We propose to measure the compression force on the sheath at the distal end so that the tension force on the tendon, which equals the compression force on the sheath, can be obtained. With this approach, a new force sensor made up of a 1 mm fiber Bragg grating attached to a 3 mm long nitinol tube was developed to measure the compression force exerted on the sheath. Mechanics analysis and verification tests were conducted to characterize the relationship between tension and compression on a TSM. Force calibrations, hysteresis study, and temperature compensation verification tests on the sensor were carried out. The force sensor has a measurement error of 0.178 N and a sensitivity of 34.14 pm/N. Applications of the sensor in a TSM-driven robotic grasper and a tendon-driven continuum robot were demonstrated. This force sensor has salient advantages: it is small, structurally simple, electrically passive, temperature-compensated, easy to assemble and disassemble, flexible, and biocompatible. This proposed approach with the new force sensor can also be applied to both TSM-driven systems and tendon-driven systems such as robotic fingers/hands, wearable devices, surgical catheters, and rehabilitation devices. | URI: | https://hdl.handle.net/10356/137856 | ISSN: | 1941-014X | DOI: | 10.1109/TMECH.2019.2951540 | Rights: | © 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: https://doi.org/10.1109/TMECH.2019.2951540 | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | MAE Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Tmech_WJ final.pdf | 1.91 MB | Adobe PDF | View/Open |
SCOPUSTM
Citations
20
21
Updated on Jan 29, 2023
Web of ScienceTM
Citations
10
23
Updated on Feb 2, 2023
Page view(s)
223
Updated on Feb 4, 2023
Download(s) 20
180
Updated on Feb 4, 2023
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.