Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/139094
Title: Highly sensitive, label-free detection of 2,4-dichlorophenoxyacetic acid using an optofluidic chip
Authors: Feng, Xueling
Zhang, Gong
Chin, Lip Ket
Liu, Ai Qun
Liedberg, Bo
Keywords: Engineering::Electrical and electronic engineering
Issue Date: 2017
Source: Feng, X., Zhang, G., Chin, L. K., Liu, A. Q., & Liedberg, B. (2017). Highly sensitive, label-free detection of 2,4-dichlorophenoxyacetic acid using an optofluidic chip. ACS Sensors, 2(7), 955-960. doi:10.1021/acssensors.7b00217
Project: NRF-CRP13-2014-01
NRF2014NRF-CRP001-002
Journal: ACS Sensors
Abstract: A highly sensitive approach for rapid and label-free detection of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) using an optofluidic chip is demonstrated. The optofluidic chip is prepared by covalent immobilization of 2,4-D-bovine serum albumin (2,4-D-BSA) conjugate to an integrated microring resonator. Subsequent detection of 2,4-D carried out in a competitive immunoreaction format enables selective detection of 2,4-D in different types of water samples, including bottled, tap, and lake water, at a limit of detection (LOD) of 4.5 pg/mL and in a quantitative range of 15-105 pg/mL. The microring resonator-based optofluidic chip is reusable with ultrahigh sensitivity that offers real-time and on-site detection of low-molecular-weight targets for potential applications in food safety and environmental monitoring.
URI: https://hdl.handle.net/10356/139094
ISSN: 2379-3694
DOI: 10.1021/acssensors.7b00217
Schools: School of Electrical and Electronic Engineering 
School of Materials Science & Engineering 
Organisations: Centre for Biomimetic Sensor Science
Rights: This document is the Accepted Manuscript version of a Published Work that appeared in final form in ACS Sensors, copyright © American Chemical Society after peer review and technical editing by the publisher. To access the final edited and published work see https://doi.org/10.1021/acssensors.7b00217
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:EEE Journal Articles

Files in This Item:
File Description SizeFormat 
Highly Sensitive Label-Free Detection of 24-Dichlorophenoxyacetic.pdf311.23 kBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 10

35
Updated on Apr 16, 2024

Web of ScienceTM
Citations 10

26
Updated on Oct 26, 2023

Page view(s)

254
Updated on Apr 18, 2024

Download(s) 50

91
Updated on Apr 18, 2024

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.