Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/139278
Title: | Vancomycin determination by disrupting electron-transfer in a fluorescence turn-on squaraine – anthraquinone triad | Authors: | Ng, Shue Mei Wu, Xiangyang Muhammad Faisal Khyasudeen Nowakowski, Paweł J. Tan, Howe-Siang Xing, Bengang Yeow, Edwin Kok Lee |
Keywords: | Science::Chemistry | Issue Date: | 2018 | Source: | Ng, S. M., Wu, X., Muhammad Faisal Khyasudeen, Nowakowski, P. J., Tan, H.-S., Xing, B., & Yeow, E. K. L. (2018). Vancomycin determination by disrupting electron-transfer in a fluorescence turn-on squaraine – anthraquinone triad. ACS Sensors, 3(6), 1156-1163. doi:10.1021/acssensors.8b00188 | Journal: | ACS Sensors | Abstract: | A highly sensitive and selective probe for Vancomycin (Van) in aqueous and serum samples is developed in this study. The probe is based on a triad consisting of a near-infrared squaraine dye (Seta-640) conjugated to two anthraquinone molecules via Lys-d-Ala-d-Ala peptides. In the absence of Van, the close proximity and efficient electron-transfer from the excited Seta-640 dye to anthraquinone result in significant fluorescence quenching of the dye (“off”-state). When Van is added, the antibiotic molecules bind with high affinity to the -d-Ala-d-Ala ligands in a 2:1 stoichiometry (Van:triad), resulting in fluorescence recovery that is as high as 30 times (“on”-state). Even though bound Van enhances the fluorescence by reducing the rate of (intrinsic) polarity-induced nonradiative decay process, this effect plays only a minor role. Instead, the main reason behind the observed fluorescence recovery after drug binding is the effective inhibition of electron-transfer; plausibly arising from a steric-induced lengthening of the spatial separation between electron donor and acceptor. The probe has detection limits of 7.0 and 96.9 nM in buffer and human serum, respectively, operates in the clinically relevant range, is insensitive to Van crystalline degradation product (CDP-1), and is easy to operate by using a commonly available fluorescence spectrometer. | URI: | https://hdl.handle.net/10356/139278 | ISSN: | 2379-3694 | DOI: | 10.1021/acssensors.8b00188 | Schools: | School of Physical and Mathematical Sciences | Rights: | © 2018 American Chemical Society. All rights reserved. | Fulltext Permission: | none | Fulltext Availability: | No Fulltext |
Appears in Collections: | SPMS Journal Articles |
SCOPUSTM
Citations
50
2
Updated on Mar 19, 2025
Web of ScienceTM
Citations
20
7
Updated on Oct 24, 2023
Page view(s)
224
Updated on Mar 21, 2025
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.