Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/139924
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCao, Linen_US
dc.contributor.authorKaan, Hung Lengen_US
dc.contributor.authorLi, Xiaoguoen_US
dc.contributor.authorPhan, Phuoc Thienen_US
dc.contributor.authorTiong, Anthony Meng Huaten_US
dc.contributor.authorHo, Khek Yuen_US
dc.contributor.authorChiu, Philip Wai Yanen_US
dc.contributor.authorPhee, Soo Jayen_US
dc.date.accessioned2020-05-22T08:40:08Z-
dc.date.available2020-05-22T08:40:08Z-
dc.date.issued2019-
dc.identifier.citationCao, L., Kaan, H. L., Li, X., Phan, P. T., Tiong, A. M. H., Ho, K. Y., . . . Phee, S. J. (2019). Endoscopic suturing using a computer-controlled master and slave robot : animal study. Surgical Endoscopy, 33(Suppl. 2), 485-781. doi:10.1007/s00464-019-07109-xen_US
dc.identifier.issn0930-2794-
dc.identifier.urihttps://hdl.handle.net/10356/139924-
dc.description.abstractBackground: Ideally, endoscopic suturing should mimic surgical closure as the latter is stronger than most endoscopic closure devices. However, endoscopic suturing is challenging due to the confined endoluminal space and lack of dexterity of current endoscopic instruments. We have developed a novel robotic suturing device to overcome these problems. Aim: This animal study aims to demonstrate the feasibility of this device in closing perforations. Method: The trial was conducted on an anaesthetized live pig. A double-channel colonoscope was first inserted into the rectum. Following saline lift, a 10 mm submucosal incision was created in the rectum to simulate a perforation. The robotic suturing device and grasper were inserted into the two colonoscope channels, allowing the endoscope to remain in position for tool exchanges or needle reloading. Both the effectors were intuitively tele-operated by the user via a robotic master console. This robotic suturing device manipulated a curved, double-point needle (with a 10 cm 3-0 Vicryl suture) to penetrate tissues at desired orientations. The needle could be switched between both jaws of the device through a locking mechanism. This facilitated passing the needle through tissues to form stitches or through suture loops to form surgical knots. The articulated joints and five degrees of freedom allowed dexterous steering to reach targets and triangulation with other tools in a confined space. The robotic grasper facilitated handling of tissue and suture. Result: A total of four running stitches were performed and secured with a surgical knot by passing the needle through suture loops. The suture was cut and the needle was removed by the robotic grasper through the channel. 11 min and 4 min were required to stitch and tie the knot respectively. There was no complication. Conclusion: Our novel endoscopic robotic device can suture perforations resulting from complex endoscopic procedures. As our suturing method is similar to laparoscopic and robotic suturing, closure using our device is expected to be as strong as a surgical through-and-through closure. When developed further, this device can be used to close full-thickness resection sites and orifices in transluminal endoscopic surgery.en_US
dc.language.isoenen_US
dc.rights© 2019 Springer Science+Business Media, LLC, part of Springer Nature. This is a post-peer-review, pre-copyedit version of an article published in Surgical Endoscopy. The final authenticated version is available online at: http://dx.doi.org/10.1007/s00464-019-07109-xen_US
dc.subjectEngineering::Mechanical engineering::Surgical assistive technologyen_US
dc.titleEndoscopic suturing using a computer-controlled master and slave robot : animal studyen_US
dc.typeJournal Articleen
dc.contributor.schoolSchool of Mechanical and Aerospace Engineeringen_US
dc.contributor.conference27th International Congress of the European Association for Endoscopic Surgery (EAES)en_US
dc.identifier.doi10.1007/s00464-019-07109-x-
dc.description.versionAccepted versionen_US
dc.identifier.pmid31520193-
dc.identifier.scopus2-s2.0-85072791321-
dc.identifier.volume33en_US
dc.identifier.spageS543en_US
dc.identifier.epageS543en_US
dc.subject.keywordsEndoscopic Surgical Robotsen_US
dc.subject.keywordsSuturing Systemen_US
dc.citation.conferencelocationSevilla, Spainen_US
item.grantfulltextopen-
item.fulltextWith Fulltext-
Appears in Collections:MAE Journal Articles
Files in This Item:
File Description SizeFormat 
EAES 2019.pdfThis conference publishes abstract only (no full paper proceeding)181.98 kBAdobe PDFView/Open

SCOPUSTM   
Citations 50

1
Updated on Mar 10, 2021

Page view(s)

158
Updated on Sep 29, 2022

Download(s)

15
Updated on Sep 29, 2022

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.