Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/140495
Title: | Hybrid AC/DC system harmonics control through grid interfacing converters with low switching frequency | Authors: | Tian, Hao Li, Yun Wei Wang, Peng |
Keywords: | Engineering::Electrical and electronic engineering | Issue Date: | 2017 | Source: | Tian, H., Li, Y. W., & Wang, P. (2018). Hybrid AC/DC system harmonics control through grid interfacing converters with low switching frequency. IEEE Transactions on Industrial Electronics, 65(3), 2256-2267. doi:10.1109/TIE.2017.2740822 | Journal: | IEEE Transactions on Industrial Electronics | Abstract: | The nonlinear loads in distribution grid may generate harmful low-order harmonics, polluting the grid and deteriorating the voltage quality particularly when the grid is weak. The grid interfacing converters in the distribution system, such as the distributed generation (DG) interfacing converters or hybrid ac/dc grid interlinking converters, can participate in distribution grid harmonic control. In this paper, two virtual-impedance-based harmonics control methods are developed for grid interfacing voltage-source inverters (VSIs) to improve the power quality of the distribution grid. As the control parameters are designed based on the virtual impedance theory, clear physical meanings are given to explain their impacts on the system. Also, the proposed methods do not rely on the closed loop feedback control and, therefore, are very suitable for VSIs with low switching frequency (such as those for high-power DGs or interlinking converters for hybrid ac/dc systems), whose closed-loop control feedback bandwidth may be limited for harmonic regulation. The influence of system delay and feedback control loop is considered and modeled in the design procedure; thus more accurate virtual impedance control is achieved for low-switching-frequency VSIs. Moreover, a comprehensive comparison of the two methods, including stability and harmonic compensation performance, are given. Their effectiveness is verified by experiment results. | URI: | https://hdl.handle.net/10356/140495 | ISSN: | 0278-0046 | DOI: | 10.1109/TIE.2017.2740822 | Rights: | © 2017 IEEE. All rights reserved. | Fulltext Permission: | none | Fulltext Availability: | No Fulltext |
Appears in Collections: | EEE Journal Articles |
SCOPUSTM
Citations
10
44
Updated on Mar 28, 2023
Web of ScienceTM
Citations
10
37
Updated on Mar 26, 2023
Page view(s)
108
Updated on Apr 1, 2023
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.