Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/140606
Title: Contribution of osmotic suction to shear strength of unsaturated high plasticity silty soil
Authors: Leong, Eng-Choon
Abuel-Naga, Hossam
Keywords: Engineering::Environmental engineering
Issue Date: 2017
Source: Leong, E.-C., & Abuel-Naga, H. (2018). Contribution of osmotic suction to shear strength of unsaturated high plasticity silty soil. Geomechanics for Energy and the Environment, 15, 65-73. doi:10.1016/j.gete.2017.11.002
Journal: Geomechanics for Energy and the Environment
Abstract: The engineering behaviour of unsaturated soils is affected by suction. It is widely accepted that soil suction consists of two major components: matric and osmotic suctions. Matric suction is associated with the capillary effects whereas osmotic suction is associated with the salt content of the pore water. Soil suction has been incorporated as “effective” stress or suction stress when describing the engineering behaviour of unsaturated soils. Usually, the suction component that is incorporated is matric suction while the contribution of osmotic suction is seldom investigated. In this paper, the contribution of osmotic suction to shear strength of unsaturated soils is investigated through unconfined compression tests on three series of compacted soil prepared using distilled water and sodium chloride solution. Specimens were prepared at three water contents corresponding to dry densities at dry of optimum, optimum and wet of optimum on the standard Proctor compaction curve. Series one and two consist of specimens compacted using distilled water and sodium chloride solution, respectively. In series three, one half of the specimen was compacted using distilled water and the other half compacted using sodium chloride solution. Unconfined compression tests were conducted on the soil specimens at various elapsed times after compaction to allow for ionic equilibrium due to the osmotic gradient in the third series of soil specimens. The test results show soil specimens have similar strength at each compaction water content regardless of elapsed time and type of pore water. No effect of osmotic suction or osmotic suction gradient on shear strength of the compacted soil specimens was found. It was concluded that the salt content of the pore water affects the soil structure of clayey soils and does not act like matric suction. Hence, matric suction should be measured in order to quantify the engineering behaviour of unsaturated soils.
URI: https://hdl.handle.net/10356/140606
ISSN: 2352-3808
DOI: 10.1016/j.gete.2017.11.002
Schools: School of Civil and Environmental Engineering 
Rights: © 2017 Elsevier Ltd. All rights reserved.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:CEE Journal Articles

SCOPUSTM   
Citations 20

24
Updated on Mar 25, 2024

Web of ScienceTM
Citations 20

19
Updated on Oct 30, 2023

Page view(s)

228
Updated on Mar 28, 2024

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.