Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/140850
Title: Performance investigation on a novel liquid desiccant regeneration system operating in vacuum condition
Authors: Yon, Hao Ren
Cai, Wenjian
Wang, Youyi
Shen, Suping
Keywords: Engineering::Electrical and electronic engineering
Issue Date: 2017
Source: Yon, H. R., Cai, W., Wang, Y., & Shen, S. (2018). Performance investigation on a novel liquid desiccant regeneration system operating in vacuum condition. Applied Energy, 211, 249-258. doi:10.1016/j.apenergy.2017.10.124
Journal: Applied Energy
Abstract: Liquid Desiccant Dehumidification Systems (LDDS) have been gaining attention due to its great energy saving potential in buildings. The desiccant regeneration system in LDDS plays a vital role in the system as the major energy consumed is due to the heat energy supplied to regain the concentration of the desiccant solution. The high regeneration temperature prohibits the potential use of low-grade or renewable energy as the heat source in the desiccant regeneration system. Therefore, a desiccant regeneration system operating in vacuum condition was proposed in this work. A novel Absorption-based Liquid Desiccant Regeneration (ALDR) system was developed and studied to validate this approach. A performance prediction model was also developed to predict the regeneration performance of the ALDR system. The model predicted values and the experimental values agreed well with each other with average deviation less than 5.90%. The operating parameters in the proposed ALDR system were also compared with the conventional packed-bed desiccant regeneration system available in literature. The regeneration temperature in LDDS was found to be significantly reduced to around 20–35 °C with the operating vacuum pressure between 1000 Pa and 2000 Pa when regenerating Lithium Bromide solution of 36% mass fraction. This study validated the feasibility of the ALDR system in reducing the regeneration temperature of the desiccant regeneration system. The results also showed that the proposed ALDR system was able to reduce the power consumption by 40.66% compared to the conventional packed-type regenerator from literature.
URI: https://hdl.handle.net/10356/140850
ISSN: 0306-2619
DOI: 10.1016/j.apenergy.2017.10.124
Schools: School of Electrical and Electronic Engineering 
Organisations: Centre for System Intelligence and Efficiency
Centre for E-City
Rights: © 2017 Elsevier Ltd. All rights reserved.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:EEE Journal Articles

SCOPUSTM   
Citations 20

24
Updated on Mar 16, 2025

Web of ScienceTM
Citations 20

18
Updated on Oct 28, 2023

Page view(s)

279
Updated on Mar 23, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.