dc.contributor.authorTrinh, Quoc Namen_US
dc.contributor.authorWang, Pengen_US
dc.contributor.authorTang, Yien_US
dc.contributor.authorChoo, Fook Hoongen_US
dc.date.accessioned2020-06-09T02:47:05Z-
dc.date.available2020-06-09T02:47:05Z-
dc.date.issued2017-
dc.identifier.citationTrinh, Q. N., Wang, P., Tang, Y., & Choo, F. H. (2018). Mitigation of DC and harmonic currents generated by voltage measurement errors and grid voltage distortions in transformerless grid-connected inverters. IEEE Transactions on Energy Conversion, 33(2), 801-813. doi:10.1109/TEC.2017.2763240en_US
dc.identifier.issn0885-8969en_US
dc.identifier.urihttps://hdl.handle.net/10356/141524-
dc.description.abstractThe dc offset and scaling errors in the voltage measurements cause the injection of undesired dc and harmonic currents into the three-phase output currents of the grid-connected inverter. This study proposes an enhanced current control scheme to eliminate the dc and harmonic currents caused by voltage distortion and voltage measurement error in three-phase grid-connected inverters. The proposed current controller is designed in the synchronous (d-q ) reference frame and composed of a proportional resonant (PR) controller and a repetitive controller (RC). The role of the RC is to regulate the grid current follow the reference value as well as compensate all 6nωs and (6n±2)ωs(n= 1,2,3,⋯) harmonic components caused by distorted grid voltage and scaling errors. Meanwhile, the PR controller helps to compensate the dc current generated by dc offset measurement errors to guarantee that the three-phase grid currents are balanced and sinusoidal with extremely low dc component. Since the RC employed in the proposed current controller reduces to time delay by four times compared to the conventional RC, the proposed control system ensures good steady-state performance of the grid current without deteriorating its fast dynamic response. The effectiveness of the suggested solution is verified by various experimental tests.en_US
dc.description.sponsorshipNRF (Natl Research Foundation, S’pore)en_US
dc.language.isoenen_US
dc.relation.ispartofIEEE Transactions on Energy Conversionen_US
dc.rights© 2017 IEEE. All rights reserved.en_US
dc.subjectEngineering::Electrical and electronic engineeringen_US
dc.titleMitigation of DC and harmonic currents generated by voltage measurement errors and grid voltage distortions in transformerless grid-connected invertersen_US
dc.typeJournal Articleen
dc.contributor.schoolSchool of Electrical and Electronic Engineeringen_US
dc.contributor.researchEnergy Research Institute @ NTU (ERI@N)en_US
dc.identifier.doi10.1109/TEC.2017.2763240-
dc.identifier.scopus2-s2.0-85047348393-
dc.identifier.issue2en_US
dc.identifier.volume33en_US
dc.identifier.spage801en_US
dc.identifier.epage813en_US
dc.subject.keywordsGrid-connected Invertersen_US
dc.subject.keywordsMeasurement Errorsen_US
item.fulltextNo Fulltext-
item.grantfulltextnone-
Appears in Collections:ERI@N Journal Articles

SCOPUSTM   
Citations 10

45
Updated on Mar 24, 2024

Web of ScienceTM
Citations 10

37
Updated on Oct 28, 2023

Page view(s)

169
Updated on Mar 28, 2024

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.