DC Field | Value | Language |
---|---|---|
dc.contributor.author | Trinh, Quoc Nam | en_US |
dc.contributor.author | Wang, Peng | en_US |
dc.contributor.author | Tang, Yi | en_US |
dc.contributor.author | Choo, Fook Hoong | en_US |
dc.date.accessioned | 2020-06-09T02:47:05Z | - |
dc.date.available | 2020-06-09T02:47:05Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | Trinh, Q. N., Wang, P., Tang, Y., & Choo, F. H. (2018). Mitigation of DC and harmonic currents generated by voltage measurement errors and grid voltage distortions in transformerless grid-connected inverters. IEEE Transactions on Energy Conversion, 33(2), 801-813. doi:10.1109/TEC.2017.2763240 | en_US |
dc.identifier.issn | 0885-8969 | en_US |
dc.identifier.uri | https://hdl.handle.net/10356/141524 | - |
dc.description.abstract | The dc offset and scaling errors in the voltage measurements cause the injection of undesired dc and harmonic currents into the three-phase output currents of the grid-connected inverter. This study proposes an enhanced current control scheme to eliminate the dc and harmonic currents caused by voltage distortion and voltage measurement error in three-phase grid-connected inverters. The proposed current controller is designed in the synchronous (d-q ) reference frame and composed of a proportional resonant (PR) controller and a repetitive controller (RC). The role of the RC is to regulate the grid current follow the reference value as well as compensate all 6nωs and (6n±2)ωs(n= 1,2,3,⋯) harmonic components caused by distorted grid voltage and scaling errors. Meanwhile, the PR controller helps to compensate the dc current generated by dc offset measurement errors to guarantee that the three-phase grid currents are balanced and sinusoidal with extremely low dc component. Since the RC employed in the proposed current controller reduces to time delay by four times compared to the conventional RC, the proposed control system ensures good steady-state performance of the grid current without deteriorating its fast dynamic response. The effectiveness of the suggested solution is verified by various experimental tests. | en_US |
dc.description.sponsorship | NRF (Natl Research Foundation, S’pore) | en_US |
dc.language.iso | en | en_US |
dc.relation.ispartof | IEEE Transactions on Energy Conversion | en_US |
dc.rights | © 2017 IEEE. All rights reserved. | en_US |
dc.subject | Engineering::Electrical and electronic engineering | en_US |
dc.title | Mitigation of DC and harmonic currents generated by voltage measurement errors and grid voltage distortions in transformerless grid-connected inverters | en_US |
dc.type | Journal Article | en |
dc.contributor.school | School of Electrical and Electronic Engineering | en_US |
dc.contributor.research | Energy Research Institute @ NTU (ERI@N) | en_US |
dc.identifier.doi | 10.1109/TEC.2017.2763240 | - |
dc.identifier.scopus | 2-s2.0-85047348393 | - |
dc.identifier.issue | 2 | en_US |
dc.identifier.volume | 33 | en_US |
dc.identifier.spage | 801 | en_US |
dc.identifier.epage | 813 | en_US |
dc.subject.keywords | Grid-connected Inverters | en_US |
dc.subject.keywords | Measurement Errors | en_US |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
Appears in Collections: | ERI@N Journal Articles |
SCOPUSTM
Citations
10
45
Updated on Mar 24, 2024
Web of ScienceTM
Citations
10
37
Updated on Oct 28, 2023
Page view(s)
169
Updated on Mar 28, 2024
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.