Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/142138
Title: Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia
Authors: Liu, Yu-Chi
Konstantopoulos, Aris
Riau, Andri K.
Bhayani, Raj
Lwin, Nyein C.
Teo, Ericia Pei Wen
Yam, Gary Hin Fai
Mehta, Jodhbir Singh
Keywords: Engineering::Materials
Issue Date: 2015
Source: Liu, Y.-C., Konstantopoulos, A., Riau, A. K., Bhayani, R., Lwin, N. C., Teo, E. P. W., . . . Mehta, J. S. (2015). Repeatability and reproducibility of corneal biometric measurements using the visante omni and a rabbit experimental model of post-surgical corneal ectasia. Translational Vision Science & Technology, 4(2), 16-. doi:10.1167/tvst.4.2.16
Journal: Translational Vision Science & Technology
Abstract: Purpose: To investigate the repeatability and reproducibility of the Visante Omni topography in obtaining topography measurements of rabbit corneas and to develop a post-surgical model of corneal ectasia. Methods: Eight rabbits were used to study the repeatability and reproducibility by assessing the intra- and interobserver bias and limits of agreement. Another nine rabbits underwent different diopters (D) of laser in situ keratosmileusis (LASIK) were used for the development of ectasia model. All eyes were examined with the Visante Omni, and corneal ultrastructure were evaluated with transmission electron microscopy (TEM). Results: There was no significant intra- or interobserver difference for mean steep and flat keratometry (K) values of simulated K, anterior, and posterior elevation measurements. Eyes underwent -5 D LASIK had a significant increase in mean amplitude of astigmatism and posterior surface elevation with time (P for trend < 0.05). At 2 and 3 months, the -5 D LASIK group had significant greater mean amplitude of astigmatism (P = 0.036; P = 0.027) and posterior surface elevation (both P < 0.005) compared with control group. On TEM, the mean collagen fibril diameter and interfibril distance in the -5 D LASIK eyes were significantly greater than in controls at 3 months (P = 0.018; P < 0.001). Conclusions: The Visante Omni provided imaging of the rabbit cornea with good repeatability and reproducibility. Application of -5 D LASIK treatment produced a rabbit model of corneal ectasia that was gradual in development and simulated the human condition. Translational Relevance: The results provide the foundations for the future evaluation of novel treatment modalities for post-surgical ectasia and keratoconus.
URI: https://hdl.handle.net/10356/142138
ISSN: 2164-2591
DOI: 10.1167/tvst.4.2.16
Rights: © 2015 Association for Research in Vision and Ophthalmology (ARVO). All rights reserved. This paper was published in Translational Vision Science & Technology and is made available with permission of Association for Research in Vision and Ophthalmology (ARVO).
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:MSE Journal Articles

SCOPUSTM   
Citations 20

7
Updated on Jul 10, 2022

PublonsTM
Citations 20

7
Updated on Jul 11, 2022

Page view(s)

169
Updated on Aug 7, 2022

Download(s)

16
Updated on Aug 7, 2022

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.