Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/143212
Title: | Magnetic field assisted preconcentration of biomolecules for lateral flow assaying | Authors: | Sharma, Antareep Tok, Alfred Iing Yoong Lee, Chleo Ganapathy, Rajasege Palaniappan, Alagappan Liedberg, Bo |
Keywords: | Engineering::Materials | Issue Date: | 2019 | Source: | Sharma, A., Tok, A. l. Y., Lee, C., Ganapathy, R., Palaniappan, A., & Liedberg, B. (2019). Magnetic field assisted preconcentration of biomolecule s for lateral flow assaying. Sensors and Actuators B: Chemical, 285, 431-437. doi:10.1016/j.snb.2019.01.073 | Journal: | Sensors and Actuators B: Chemical | Abstract: | Lateral flow assays (LFA) have been extensively explored for rapid and cost effective point-of-care diagnostics. Typically, LFA responses are influenced by the complexity of sample matrices containing analogues or molecules that may potentially yield non-specific responses, for instance, when assaying for biomarkers in blood, serum and plasma. Therefore, isolation of analytes of interest from sample matrices would significantly improve the LFA responses. Herein, we report a magnetic field assisted preconcentration approach for extraction and assay of proteins in an LFA format. Cardiac marker, Troponin (cTnICT complex), is utilized as a model system for validation of the proposed approach. Magnetic fields of different strengths are evaluated for retaining cTnICT on an LFA membrane utilizing magnetic beads conjugated with anti-Troponin I (anti-TnI) antibodies. The sample matrix components subsequently flows through to the absorbent pad via a hydrophilic passivation layer that is protecting the capturing anti-Troponin C (anti-TnC) antibodies in the test zone. Isolated TnI-magnetic bead complexes are then released to flow downstream along the LFA strip to the test zone upon removal of magnetic field and the passivation layer. The capture of cTnICT magnetic bead complexes at the test zone produces a characteristic brownish band, enabling concentration dependant visual detection of cTnICT. Experimental results indicate that the assay yields pM level sensitivity within 15 min using very low sample volumes (<100 μL), and with possibilities for signal enhancement. The reported assay offers a promising avenue for sensitive detection of target analytes in complex matrices at clinically relevant concentration levels without requiring tedious sample pre-treatment protocols. | URI: | https://hdl.handle.net/10356/143212 | ISSN: | 0925-4005 | DOI: | 10.1016/j.snb.2019.01.073 | Rights: | © 2019 Elsevier B.V. All rights reserved. This paper was published in Sensors and Actuators B: Chemical and is made available with permission of Elsevier B.V. | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | IGS Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Magnetic field assisted preconcentration of biomolecules for lateral flow assaying.pdf | 1.28 MB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
20
10
Updated on Mar 10, 2021
PublonsTM
Citations
20
8
Updated on Mar 5, 2021
Page view(s)
185
Updated on Jun 27, 2022
Download(s) 50
49
Updated on Jun 27, 2022
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.