Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/145623
Title: A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation
Authors: Lan, Yisha
Zhou, Yuanhang
Lu, Yiwen
Wang, Hao
Liu, Qing
Ng, Eddie Yin Kwee
Peng, Yonghong
Hao, Yongtao
Liu, Qinyuan
Chen, Fei
Cheng, Yongqiang
Che, Wenliang
Keywords: Engineering::Electrical and electronic engineering
Issue Date: 2019
Source: Lan, Y., Zhou, Y., Lu, Y., Wang, H., Liu, Q., Ng, E. Y. K., . . . Che, W. (2019). A nine months follow-up study of hemodynamic effect on bioabsorbable coronary stent implantation. IEEE Access, 7, 112564-112571. doi:10.1109/ACCESS.2019.2934155
Journal: IEEE Access 
Abstract: Coronary artery disease has emerged as one of the major diseases causing death worldwide. Coronary stent has great effect to improve blood flow to the myocardium subtended by that artery, in which bioresorbable vascular scaffolds are new-generation stents used by people. However, Coronary stents implantation has a risk of restenosis, which is relative to hemodynamic parameters. Most of existing literatures studied in this issue have not taken into account such important factors as the strut thickness and lumen profile, and has yet to analyze the time effects among hemodynamic parameters over a certain period of time based on individual models. In this research, we proposed a framework to assess the chronic impact of hemodynamic on coronary stent implantation. In the framework, the optical coherence tomography (OCT) is combined with angiography to reconstruct patient-specific models of bioresorbable vascular scaffolds. Then, the hemodynamics parameters are extracted through the simulated 3D models, obtaining the distribution of wall shear stress (WSS), relative residence time (RRT) and oscillatory shear index (OSI). Finally, the changes of these parameters representing the effectiveness of hemodynamics exerted on the implanted stent can be assessed to estimate the chronic impacts. By a 9-month follow-up case study, it is observed that the difference of hemodynamic parameters are not significance. Both at baseline and 9-month follow-up experiments show that the hemodynamic parameters remain normal and similar, proving that the coronary stent implantation nowadays appears to have a robust and everlasting curative effect.
URI: https://hdl.handle.net/10356/145623
ISSN: 2169-3536
DOI: 10.1109/ACCESS.2019.2934155
Schools: School of Mechanical and Aerospace Engineering 
Rights: © 2019 The Author(s). This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see http://creativecommons.org/licenses/by/4.0/
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:MAE Journal Articles

Files in This Item:
File Description SizeFormat 
08793063.pdf1.47 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 50

2
Updated on Apr 23, 2025

Web of ScienceTM
Citations 50

1
Updated on Oct 27, 2023

Page view(s)

346
Updated on May 7, 2025

Download(s) 50

110
Updated on May 7, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.