Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/146184
Title: Surface texture measurement on complex geometry using dual-scan positioning strategy
Authors: Cheng, Fang
Fu, Shaowei
Chen, Ziran
Keywords: Engineering::Mechanical engineering
Issue Date: 2020
Source: Cheng, F., Fu, S., & Chen, Z. (2020). Surface texture measurement on complex geometry using dual-scan positioning strategy. Applied Sciences, 10(23), 8418-. doi:10.3390/app10238418
Journal: Applied Sciences
Abstract: In this paper, a surface measurement method based on dual-scan positioning strategy is presented to address the challenges of irregular surface patterns and complex geometries. A confocal sensor with an internal scanning mechanism was used in this study. By synchronizing the local scan, enabled by the internal actuator in the confocal sensor, and the global scans, enabled by external positioners, the developed system was able to perform noncontact line scan and area scan. Thus, this system was able to measure both surface roughness and surface uniformity. Unlike laboratory surface measurement equipment, the proposed system is reconfigurable for in situ measurement and able to scan free-form surfaces with a proper stand-off distance and approaching angle. For long-travel line scan, which is needed for rough surfaces, a surface form tracing algorithm was developed to ensure that the data were always captured within the sensing range of the confocal sensor. It was experimentally verified that in a scanning length of 100 mm, where the surface fluctuation in vertical direction is around 10 mm, the system was able to perform accurate surface measurement. For area scan, XY coordinates provided by the lateral positioning system and the Z coordinate captured by the confocal sensor were plotted into one coordinate system for 3D reconstruction. A coherence scanning interferometer and a confocal microscope were employed as the reference measurement systems to verify the performance of the proposed system in a scanning area of 1 mm by 1 mm. Experimental data showed that the proposed system was able to achieve comparable accuracy with laboratory systems. The measurement deviation was within 0.1 µm. Because line scan mechanisms are widely used in sensor design, the presented work can be generalized to expand the applications of line scan sensors.
URI: https://hdl.handle.net/10356/146184
ISSN: 2076-3417
DOI: 10.3390/app10238418
Schools: School of Mechanical and Aerospace Engineering 
Rights: © 2020 The Author(s). Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution(CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Fulltext Permission: open
Fulltext Availability: With Fulltext
Appears in Collections:MAE Journal Articles

Files in This Item:
File Description SizeFormat 
applsci-10-08418-v2-1.pdf6.14 MBAdobe PDFThumbnail
View/Open

SCOPUSTM   
Citations 50

7
Updated on Sep 22, 2023

Web of ScienceTM
Citations 50

5
Updated on Sep 21, 2023

Page view(s)

113
Updated on Sep 27, 2023

Download(s) 50

85
Updated on Sep 27, 2023

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.