Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/149238
Title: | PVC-based ion-selective electrodes with a silicone rubber outer coating with improved analytical performance | Authors: | Joon, Narender Kumar He, Ning Ruzgas, Tautgirdas Bobacka, Johan Lisak, Grzegorz |
Keywords: | Science::Chemistry::Analytical chemistry | Issue Date: | 2019 | Source: | Joon, N. K., He, N., Ruzgas, T., Bobacka, J. & Lisak, G. (2019). PVC-based ion-selective electrodes with a silicone rubber outer coating with improved analytical performance. Analytical Chemistry, 91(16), 10524-10531. https://dx.doi.org/10.1021/acs.analchem.9b01490 | Journal: | Analytical Chemistry | Abstract: | An outer layer of pure silicone rubber (SR), i.e. SR without any plasticizer, ionophore, or lipophilic anion, was applied on top of a conventional poly(vinyl chloride) (PVC) based K+-selective membrane in a solid-contact ion-selective electrode (SC-ISE). The influence of the outer SR coating on the analytical performance of the K+-ISEs was studied. The presence of the SR coating did not affect the selectivity of the SC-ISE, indicating that the plasticizer, ionophore, and lipophilic anion are spontaneously distributed from the PVC-based membrane into the SR layer. This was confirmed by electrochemical impedance spectroscopy (EIS). Interestingly, the reproducibility of the standard potential of the conditioned SC-ISE was significantly improved from E0 ± 35.3 mV to E0 ± 3.5 mV simply by adding the SR coating on top of the plasticized PVC based K+-selective membrane. Moreover, the adsorption of bovine serum albumin (BSA) was significantly reduced at the SR coated ion-selective membrane. Thus, the addition of a SR coating on a plasticized PVC ion-selective membrane seems to be a feasible method to improve the analytical performance and to reduce the biofouling of potentiometric ion sensors. | URI: | https://hdl.handle.net/10356/149238 | ISSN: | 1520-6882 | DOI: | 10.1021/acs.analchem.9b01490 | Rights: | This document is the Accepted Manuscript version of a Published Work that appeared in final form in Analytical Chemistry, copyright © American Chemical Society after peer review and technical editing by the publisher. To access the final edited and published work see https://doi.org/10.1021/acs.analchem.9b01490 | Fulltext Permission: | open | Fulltext Availability: | With Fulltext |
Appears in Collections: | NEWRI Journal Articles |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
20190322-Double-layered-membrane_NJ_JB.pdf | 506.44 kB | Adobe PDF | ![]() View/Open |
SCOPUSTM
Citations
20
7
Updated on May 30, 2021
PublonsTM
Citations
10
18
Updated on May 30, 2021
Page view(s)
145
Updated on Jun 27, 2022
Download(s) 50
54
Updated on Jun 27, 2022
Google ScholarTM
Check
Altmetric
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.