Please use this identifier to cite or link to this item:
https://hdl.handle.net/10356/149535
Title: | Respiratory sound classification : sensor design | Authors: | Goh, Xin Ni | Keywords: | Engineering::Electrical and electronic engineering::Control and instrumentation::Medical electronics | Issue Date: | 2021 | Publisher: | Nanyang Technological University | Source: | Goh, X. N. (2021). Respiratory sound classification : sensor design. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/149535 | Project: | A3203-201 | Abstract: | Pulmonary Edema is caused by the extravascular movement of fluid into the pulmonary interstititium and alveoli. This condition is a precursor to diseases that are principal causes of death such as Pneumonia and Chronic Obstructive Lung Diseases/Chronic Obstructive Pulmonary Disease. With the introduction of chest auscultation and later, the development of the stethoscope, practitioners had a more objective means in detecting Pulmonary Edema through the detection of adventitious sounds when patients inspire. To maintain the benefits that a stethoscope can offer and overcome the limitations of other more advanced and expensive detection methods, research on the development of an electronic stethoscope with acoustic-based techniques are conducted and gaining traction within the medical research community. This project aims to develop the electronic stethoscope chest piece using 3D printing technique and explore the various sensor housing designs based on the replication of an actual stethoscope chest piece. The project utilises the Autodesk Fusion 360 software to develop a total of 16 sensor housing design renderings, across 4 Series and 4 Types. The 16 sensor housing designs are 3D printed over five 3D printing sessions at both the Garage@EEE and SPMS Making and Tinkering Space. To facilitate the 3D printing process, the MakerBot Application software was used to convert the Fusion 360 renderings to printable files for 3D printing. Finally, the 3D printed models undergo a test where audio clips are recorded through the sensor housing and compared against the baseline audio clips to determine the sensor housing with the highest accuracy of sound detection and replication. To record and analyse the audio clips, the Audacity software was used. The project concluded that all sensor housing designs were able to replicate the baseline audio clips of varying quality. It was deemed that the Series 4 Type C sensor housing design has the best sensor design as it was able to replicate the baseline audio clips accurately and of high degree. The sensor design could potentially be explored further such as with the use of different materials etc. | URI: | https://hdl.handle.net/10356/149535 | Schools: | School of Electrical and Electronic Engineering | Fulltext Permission: | restricted | Fulltext Availability: | With Fulltext |
Appears in Collections: | EEE Student Reports (FYP/IA/PA/PI) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
U1721802G Goh Xin Ni FYP Final Report V3.pdf Restricted Access | 4.56 MB | Adobe PDF | View/Open |
Page view(s)
241
Updated on Mar 26, 2024
Download(s)
14
Updated on Mar 26, 2024
Google ScholarTM
Check
Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.