Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/149833
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSutantyo, Samuel Kurniawanen_US
dc.date.accessioned2021-05-20T02:01:04Z-
dc.date.available2021-05-20T02:01:04Z-
dc.date.issued2021-
dc.identifier.citationSutantyo, S. K. (2021). Seismic performance of corroded reinforced concrete column-slab connections. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/149833en_US
dc.identifier.urihttps://hdl.handle.net/10356/149833-
dc.description.abstractThis final year project investigated the effect of steel reinforcement corrosion towards the behaviour of reinforced concrete (RC) Flat Plate Slab-Column connections subjected to reversed cyclic loading. Flat plate RC system has been used predominantly around the world due to the ease and speed of making the formwork. Aside from that, beams and drop panel are also omitted, which permits the higher floor to floor height. Flat plates, however, do come with some disadvantages of its own. Due to the lack of any shear reinforcement and drop panel, the slab-column connection is susceptible punching failure, especially when the building is also subjected to earthquake loadings. The condition is further worsened by corrosion of rebars inside the concrete, which effectively reduces the ultimate strength capacity of the connections. Thus, in this report, analytical investigations and simulations were conducted to observe the effect of corrosions on the ultimate strength and drift capacity of slab-column connections under simulated seismic loadings. To simulate the behaviour of RC slab column connections under the loadings, non-linear Finite Element Analysis using DIANA 9.44 was used. Total strain rotate crack model was applied to design the RC joints. To ensure the accuracy of the simulation software, several validations were made using non-corroded slab column joints from various papers. Parametric study was done to observe the influence of different parameters. These parameters include corrosion levels, axial force ratio, slab reinforcement ratio, and slab thickness. The results obtained would then be used to propose an equation to predict the ultimate strength of corroded slab-column joints.en_US
dc.language.isoenen_US
dc.publisherNanyang Technological Universityen_US
dc.relationST-05en_US
dc.subjectEngineering::Civil engineering::Structures and designen_US
dc.titleSeismic performance of corroded reinforced concrete column-slab connectionsen_US
dc.typeFinal Year Project (FYP)en_US
dc.contributor.supervisorLi Bingen_US
dc.contributor.schoolSchool of Civil and Environmental Engineeringen_US
dc.description.degreeBachelor of Engineering (Civil)en_US
dc.contributor.supervisoremailCBLi@ntu.edu.sgen_US
item.grantfulltextrestricted-
item.fulltextWith Fulltext-
Appears in Collections:CEE Student Reports (FYP/IA/PA/PI)
Files in This Item:
File Description SizeFormat 
FYP_ST05_Samuel K Sutantyo.pdf
  Restricted Access
8.71 MBAdobe PDFView/Open

Page view(s)

103
Updated on Jun 25, 2022

Download(s)

14
Updated on Jun 25, 2022

Google ScholarTM

Check

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.