Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/150405
Title: Enhancing fouling mitigation of submerged flat-sheet membranes by vibrating 3D-spacers
Authors: Tan, Yong Zen
Mao, Ziming
Zhang, Yanjun
Tan, Wen See
Chong, Tzyy Haur
Wu, Bing
Chew, Jia Wei
Keywords: Engineering::Environmental engineering
Issue Date: 2019
Source: Tan, Y. Z., Mao, Z., Zhang, Y., Tan, W. S., Chong, T. H., Wu, B. & Chew, J. W. (2019). Enhancing fouling mitigation of submerged flat-sheet membranes by vibrating 3D-spacers. Separation and Purification Technology, 215, 70-80. https://dx.doi.org/10.1016/j.seppur.2018.12.085
Project: MOE2014-T2-2-074
ARC16/15
2015-T1-001-023
RG7/15
SGP-PROG3-019
Journal: Separation and Purification Technology
Abstract: Unsteady-state shear is acknowledged to be more energy-efficient in the mitigation of membrane fouling. In this study, we aimed to understand the effects of three dimensional (3D)-spacer configuration and their vibrating orientation on the extent of fouling mitigation in a submerged flat-sheet membrane microfiltration (MF) system. Several types of 3D-spacers were designed and computational fluid dynamics (CFD) was used to simulate the shear and turbulence along the membrane surface induced by vibrating 3D-spacers. The designed 3D-spacers were produced by 3D printing technique and their fouling control efficiencies were experimentally examined in a submerged flat-sheet membrane MF system with bentonite and sodium alginate as model foulants. Both simulation and experimental results revealed that the wave-like spacer (groove direction vertical to spacer movement direction) could alleviate more membrane fouling than the other designed spacers (e.g., hill-like spacer, wave-like spacer with groove direction parallel to spacer movement direction), regardless of tested permeate fluxes. Furthermore, two types of wave-like spacers were designed based on CFD simulation, in which perforation were placed on the spacer in order to enhance shear rate and provide a path for the back transport of foulants into the bulk feed. The MF membrane tests showed that the presence of either big holes (2 mm diameter) or small holes (1 mm diameter) could not benefit to reduce membrane fouling at a lower permeate flux (20 L/m² h), but the presence of small holes significantly improved membrane performance at a higher permeate flux (40 and 60 L/m² h).
URI: https://hdl.handle.net/10356/150405
ISSN: 1383-5866
DOI: 10.1016/j.seppur.2018.12.085
Rights: © 2019 Elsevier B.V. All rights reserved.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:CEE Journal Articles
IGS Journal Articles
MAE Journal Articles
NEWRI Journal Articles
SC3DP Journal Articles
SCBE Journal Articles

SCOPUSTM   
Citations 10

16
Updated on Sep 12, 2021

PublonsTM
Citations 20

14
Updated on Sep 8, 2021

Page view(s)

44
Updated on Sep 23, 2021

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.