Title: Study of heat transformation systems for cooling, heat pumps and desalination
Authors: Lee, Jia Wei
Keywords: Science::Physics::Heat and thermodynamics
Engineering::Mathematics and analysis::Simulations
Science::Mathematics::Applied mathematics::Simulation and modeling
Engineering::Mechanical engineering
Issue Date: 2021
Publisher: Nanyang Technological University
Source: Lee, J. W. (2021). Study of heat transformation systems for cooling, heat pumps and desalination. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/150705
Project: B231
Abstract: This report studies about UiO66 (Zr) and its functionalised group (-OH, -N, and -NH2) with H2O as compatible working adsorbate-adsorbent pairs that is being deployed in the adsorption assisted heat transformation (AHT) system for cooling, heating, and desalination of water. This report consists of literature reviews on AHT system and metal-organic frameworks, thermodynamics modelling, and detailed simulation results. Employing experimentally confirmed isotherms and kinetics data of MOFs – water systems, a simulation study for each component of AHT system is conducted to predict the overall performances of AHT system in terms of specific cooling power, coefficient of performance (for both heating and cooling), specific heating power and specific daily water production. These performance parameters are calculated for various operating conditions such as hot water (heat source) inlet temperature, chilled-water inlet temperature, switching and cycle time. The isotherms and kinetics data are fitted with modified Langmuir equation. The thermodynamic modelling is based on simple mass and energy balance approaches. Hence, a lumped approach is considered for simplicity. The parent UiO66 (Zr) MOFs are not found suitable for cooling applications due to its longer hydrophobic length in the low pressure region with water adsorption. Therefore, MOF-linker-functionalisation strategy is considered. Hence, pyridine, amino, and hydroxyl functional groups based UiO-66 (Zr) MOFs + water assisted AHT are simulated. It is found that -N MOF has improved SDWP of 28 m3 per ton of MOF per day as compared to parent MOF which is only 18 m3 per ton of MOF per day. -OH MOF has SCP of 0.6 kW/kg whereas parent MOF only has 0.04 kW/kg at 80 °C and 500 s half cycle time. -OH MOF has SHP of 1.1 kW/kg whereas parent MOF only has 1 kW/kg at 80 °C and 100 s half cycle time. These results confirm that functionalised UiO-66 (Zr) MOFs are competent candidates for adsorption cooling, heat pump and desalination applications.
URI: https://hdl.handle.net/10356/150705
Fulltext Permission: restricted
Fulltext Availability: With Fulltext
Appears in Collections:MAE Student Reports (FYP/IA/PA/PI)

Files in This Item:
File Description SizeFormat 
FYP_Lee Jia Wei_30May.pdf
  Restricted Access
B231: STUDY OF HEAT TRANSFORMATION SYSTEMS FOR COOLING, HEAT PUMPS AND DESALINATION1.1 MBAdobe PDFView/Open

Page view(s)

67
Updated on Dec 7, 2021

Download(s)

3
Updated on Dec 7, 2021

Google ScholarTM

Check

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.