Please use this identifier to cite or link to this item: https://hdl.handle.net/10356/152434
Title: Electron spin resonance evidence for electro-generated hydroxyl radicals
Authors: Pei, Shuzhao
You, Shijie
Ma, Jun
Chen, Xiaodong
Ren, Nanqi
Keywords: Engineering::Materials
Issue Date: 2020
Source: Pei, S., You, S., Ma, J., Chen, X. & Ren, N. (2020). Electron spin resonance evidence for electro-generated hydroxyl radicals. Environmental Science and Technology, 54(20), 13333-13343. https://dx.doi.org/10.1021/acs.est.0c05287
Project: NRF2017NRF-NSFC001-048
Journal: Environmental Science and Technology
Abstract: Electro-generated hydroxyl radicals (•OH) are of fundamental importance to the electrochemical advanced oxidation process (EAOP). Radical-specific electron spin resonance (ESR) evidence is still lacking in association with the direct electron transfer (DET) reaction of spin trap (e.g., 5,5-dimethyl-1-pyrroline-N-oxide; DMPO) and side reactions of the DMPO-OH adduct in the strongly oxidative environment offered by anodic polarization. Herein, we showed ESR identification of electro-generated •OH in EAOP based on the principle of kinetic selection. Excessive addition of a DMPO agent and fast spin trapping allowed suitable kinetic conditions to be set for effective spin trapping of electro-generated •OH and subsequent ESR identification. Otherwise, interferential triplet signals would emerge due to formation of paramagnetic dimer via dehydrogenation, DET oxidation, and dimerization reactions of the DMPO-OH adduct. The results demonstrate that •OH formation during spin-trapping on the titanium suboxide (TiSO) anode could be quantified as 47.84 ± 0.44 μM at current density of 10 mA cm-2. This value revealed a positive dependence on electrolysis time, current density, and anode potential. The effectiveness of ESR measurements was verified by the results obtained with the terephthalic acid probe. The ESR identification not only provides direct evidence for electro-generated •OH from a fundamental point of view, but also suggests a strategy to screen effective anode materials.
URI: https://hdl.handle.net/10356/152434
ISSN: 0013-936X
DOI: 10.1021/acs.est.0c05287
Rights: © 2020 American Chemical Society. All rights reserved.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:MSE Journal Articles

SCOPUSTM   
Citations 20

10
Updated on Dec 28, 2021

Page view(s)

111
Updated on May 23, 2022

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.