Title: An energy-saving oriented air balancing method for demand controlled ventilation systems with branch and black-box model
Authors: Cui, Can
Zhang, Xin
Cai, Wenjian
Keywords: Engineering::Electrical and electronic engineering
Issue Date: 2020
Source: Cui, C., Zhang, X. & Cai, W. (2020). An energy-saving oriented air balancing method for demand controlled ventilation systems with branch and black-box model. Applied Energy, 264, 114734-. https://dx.doi.org/10.1016/j.apenergy.2020.114734
Journal: Applied Energy
Abstract: This paper proposes an energy-saving oriented air balancing method based on a branch and black-box (B2) model for multi-zone demand controlled ventilation (DCV) systems. The proposed method can achieve accurate air flow control in each zone, which avoids unnecessary energy consumption caused by over-ventilation. The operating procedures of the proposed method are as follows: Building the B2 model for the DCV system → Predicting the terminal static pressures under the given zone design flow values → Determining the damper angles of each zone based on the static pressure predictions. In the proposed air balancing method, the basic modelling unit is the duct branch, instead of the internal fittings in the previous model-based air balancing method. Therefore, the proposed method does not need to know the complicated fitting information (e.g., elbows, transitions, dampers, etc.,) in its modelling process and therefore becomes much simpler. In addition, the complexity of the proposed B2 model is also greatly reduced since it is independent with the fitting numbers and does not need to calculate the fitting loss coefficients. Furthermore, the radial basis function (RBF) kernel is also utilized in the proposed method to guarantee the air balancing accuracy. Compared with the existing air balancing methods, the proposed method is more efficient and effective in practice. In the lab, the proposed air balancing method was validated on a real DCV system of 5 zones under various design flow conditions. The experimental results verified the effectiveness of the proposed method on both the air balancing control accuracy and the energy saving ability.
URI: https://hdl.handle.net/10356/155498
ISSN: 0306-2619
DOI: 10.1016/j.apenergy.2020.114734
Schools: School of Electrical and Electronic Engineering 
Rights: © 2020 Elsevier Ltd. All rights reserved.
Fulltext Permission: none
Fulltext Availability: No Fulltext
Appears in Collections:EEE Journal Articles

SCOPUSTM   
Citations 20

28
Updated on May 5, 2025

Web of ScienceTM
Citations 20

20
Updated on Oct 29, 2023

Page view(s)

170
Updated on May 5, 2025

Google ScholarTM

Check

Altmetric


Plumx

Items in DR-NTU are protected by copyright, with all rights reserved, unless otherwise indicated.